The V-Type Uterine Manipulator from Bharat Surgical is a reusable gynecological instrument designed for controlled uterine positioning during laparoscopic and selected open pelvic procedures. Its adjustable mechanism enables the surgical team to mobilize and stabilize the uterus to improve access and visualization during surgery.
Bharat Surgical’s currently listed model features a stainless-steel construction, atraumatic rounded tip, adjustable articulation, single channel and small, medium and large cup options. Because dimensions and included accessories are not fully stated in the public listing, hospitals and distributors should obtain a component-wise technical quotation before ordering.
A V-Type Uterine Manipulator is a manually operated surgical instrument used to position and mobilize the uterus during selected gynecological procedures. It is introduced transvaginally and operated by a trained surgeon or surgical assistant.
Depending on the supplied configuration, the instrument may help provide:
The term “V-Type” refers to the instrument’s design pattern or configuration. It should not automatically be interpreted as a V-shaped intrauterine tip. Bharat Surgical’s current listing describes its model as having an atraumatic rounded tip.
| Specification | Listed or Configurable Detail |
|---|---|
| Product name | V-Type Uterine Manipulator |
| Alternate catalogue name | Uterine Manipulator V |
| Product category | Gynecology and laparoscopic instruments |
| General function | Uterine positioning and manipulation |
| Operation | Manual |
| Usage | Reusable |
| Main material | Stainless steel |
| Tip type | Atraumatic rounded tip |
| Cup sizes | Small, medium and large |
| Articulation | Adjustable |
| Channel | Single channel |
| Surface finish | Polished |
| Colour | Silver and blue |
| Sterilization | Autoclavable when permitted by the supplied IFU |
| Application | Selected gynecological and laparoscopic procedures |
| Brand | Bharat Surgical |
| Country of origin | India |
Depending on the ordered configuration, a V-Type Uterine Manipulator set may include:
The final quotation should state precisely which components are included.
Bharat Surgical lists a single-channel configuration, but its specific function is not defined on the current product page. Before purchasing, obtain written confirmation of the channel’s intended function, internal diameter, connector type, permitted fluid/gas, operating limits, cleaning method, and sterilization compatibility.
Subject to the exact model, patient selection and instructions for use, a V-Type Uterine Manipulator may be considered for:
Not every configuration is suitable for every procedure. The operating surgeon must confirm suitability based on the supplied device and clinical circumstances.
| Manipulator type | Main procurement consideration |
|---|---|
| V-Type Manipulator | Reusable adjustable pattern with rounded tip, multiple cup options and a single channel |
| Cohen Manipulator | Often considered for comparatively straightforward uterine manipulation or selected injection applications |
| Mangeshikar Type | Multi-component system commonly associated with advanced laparoscopic hysterectomy |
| Marva Manipulator | Available in simple and special configurations in the Indian market |
| Sukhadia Manipulator | Reusable pattern available with configurable colpotomy components |
| Storz Type | Modular full-set pattern with multiple tips and cups |
| Tintara Manipulator | Alternative reusable pattern selected according to surgeon preference |
The names describe different instrument patterns; they do not establish common dimensions or cross-brand compatibility.
Before use, inspect shaft alignment, tips, cups, locks, articulation, channel patency, and sterilization status.
Principal Risks: Potential complications include uterine perforation, cervical/vaginal trauma, bleeding, infection, pain/cramping, tissue-pressure injury, thermal injury near energy devices, and component separation.
Insertion and operation must be performed solely by trained healthcare professionals. Avoid excessive force or rotational pressure.
Follow the validated instructions supplied with the instrument: prompt pre-cleaning, disassemble removable parts, open/unlock movable parts, rinse, clean with neutral detergent, brush joints/threads, flush single channel, rinse, dry, inspect, package, and sterilize using a validated cycle.
Bharat Surgical supplies V-Type Uterine Manipulators, complete or customized sets, cup options, replacement components, and tender support to hospitals, distributors, and export buyers.
When requesting a quotation, please provide:
Technical, component, safety and reprocessing answers for the Bharat Surgical V-Type Uterine Manipulator range.
It is a reusable gynecological instrument used to position, mobilize and stabilize the uterus during selected laparoscopic procedures.
It refers to the instrument’s design pattern or configuration. It does not necessarily mean the intrauterine tip is V-shaped.
The current product listing specifies an atraumatic rounded tip.
Yes. Bharat Surgical lists the instrument as reusable.
The main instrument is listed as stainless steel with applicable medical-grade components.
Yes. Adjustable articulation is listed for the current configuration.
Small, medium and large cup options are listed. Their actual diameters should be confirmed.
Yes. Bharat Surgical lists a single-channel configuration.
The public listing does not define its exact function. Buyers must confirm whether it is intended for suction, injection, insufflation or another approved purpose.
Only if the supplied configuration is specifically designed and approved for dye injection. A single channel alone does not confirm this function.
Only when a suitable sealing component is included and the manufacturer approves that use.
It may be used for selected hysterectomy procedures when the supplied model is suitable and the surgeon determines its use is appropriate.
It may be considered when uterine positioning is required and the product’s instructions permit that application.
An adjustable manipulator may support controlled uterine positioning, but the exact available movements and range should be confirmed for the selected model.
Bharat Surgical describes it as autoclavable. The validated temperature, exposure time and drying parameters must be obtained from its instructions.
Replacement cups may be available, but the diameter and connection design must match the existing instrument.
Compatibility must never be assumed. Connections, threads, dimensions and locking mechanisms can differ.
Cup selection depends on cervical and vaginal anatomy, the planned procedure, surgeon preference and the manufacturer’s instructions.
Check the tip, cups, shaft, handle, locks, articulation, channel, connections, cleanliness and sterilization status.
Potential risks include uterine perforation, cervical or vaginal trauma, bleeding, infection, excessive tissue pressure and component separation.
Medical and Procurement Disclaimer: All dimensions, cup sizes, tip lengths, materials, channel connections and sterilization parameters must be verified against the final quotation and product instructions. Next Level 4 page: Tintara Uterine Manipulator.