ISO 13485:2016 Certified
40+ Years of Excellence
600+ Products
Download Catalog
MANUFACTURER & SUPPLIER | B2B GYNAECOLOGY INSTRUMENTS

Mangeshikar-Type Uterine Manipulator Manufacturer and Supplier in India

Bharat Surgical offers reusable Mangeshikar-type uterine manipulators for controlled mobilisation and positioning of the uterus during selected laparoscopic gynaecological procedures. Different handle mechanisms, intrauterine elements, cervical holding components and procedure-specific accessories may be supplied according to the selected model.

Hospitals, gynaecologists, laparoscopic surgery centres, medical colleges, surgical instrument dealers and distributors can contact Bharat Surgical for complete sets, replacement components and bulk-order quotations.

ISO 13485:2016 Certified
40+ Years Experience
Mumbai Warehousing
Mangeshkar Uterine Manipulator surgical instrument on a clean clinical blue background
Overview

Reusable Mangeshikar-Type Uterine Manipulator

A Mangeshikar-type uterine manipulator is a mechanical gynaecological instrument designed to mobilise and position the uterus during minimally invasive surgery.

Depending on the selected system, it may include:

Operating handle
Main shaft
Cervical tenaculum or holding component
Intrauterine element
Sliding and fixation shaft
Cervical or vaginal tube
Insulating ring
Locking clasp
Multiple tube or cup sizes and intrauterine-tip sizes
Sterilisation tray

The exact Bharat Surgical configuration must be documented because simplified Indian-market models and advanced multi-component systems can differ substantially.

Brand and Product-Naming Disclosure

The Mangeshikar Uterine Manipulator is an established product name associated with a system developed in collaboration with Prof. Dr. Prashant Mangeshikar and marketed by Bissinger.

Bharat Surgical should describe its product according to what it actually supplies:

Original Mangeshikar Uterine Manipulator—only if supplied genuinely through an authorised channel
Mangeshikar-Type Uterine Manipulator—for Bharat Surgical’s own comparable pattern
Reusable Uterine Manipulator with Tenaculum—when no original-system compatibility is established

A similar shape does not prove compatibility with original handles, shafts, tubes, intrauterine elements or accessories.

Functions & Parts

What Is It Used For and System Components

What Is the Mangeshikar-Type Manipulator Used For?

Depending on the model and approved intended use, it may assist with:

Uterine elevation
Anteversion and retroversion
Lateral uterine movement
Uterine stabilisation
Exposure of anterior, posterior and lateral uterine anatomy
Mobilisation during total laparoscopic hysterectomy
Selected laparoscopic hysterectomy and myomectomy procedures
Pelvic dissection requiring uterine positioning
Delineation or protection of adjacent anatomy where supported by the complete system

The exact clinical capability depends on the instrument’s components. A simplified tenaculum-style model should not be given the claims of an advanced multi-component hysterectomy system.

Key System Components

Handle: Allows the operator to control and reposition the uterus. Handle options may include forceps-style, ratchet or another mechanical configuration.

Main Shaft & Cervical Tenaculum: Connects the handle with distal components, while the tenaculum engages the cervix in systems designed with an integrated cervical holding mechanism.

Intrauterine Element & Sliding Shaft: Dimension-specific elements placed within the uterine cavity, secured via a sliding and fixation shaft.

Cervical/Vaginal Tube & Insulating Ring: Provides a procedure-specific distal interface, with advanced systems offering multiple tube diameters and insulating components.

Specifications

Product Features and Technical Specifications

Product Features

Features vary by model and may include:

Reusable mechanical construction
Forceps or ratchet handle
Integrated cervical tenaculum
Interchangeable intrauterine elements
Multi-directional uterine movement
Adjustable fixation
Multiple tube or cup sizes
Detachable and modular assembly
Procedure-specific insulating component
Replaceable system parts
Complete-set or component-only supply
Sterilisation-tray option
Institutional and bulk packing

Only features verified for Bharat Surgical’s supplied model should be published.

Technical Specification Options

SpecificationAvailable selection
ProductMangeshikar-type uterine manipulator
OperationManual
Primary functionUterine mobilisation and positioning
HandleForceps, ratchet or specified design
Cervical holdingIntegrated tenaculum or separate component
Intrauterine elementFixed or interchangeable
Number of intrauterine sizesAccording to supplied set
Tube or cupFixed or interchangeable
Tube diameterModel-specific
Shaft diameterAccording to selected design
Working/Total lengthMust be confirmed
FixationSliding, clasp or ratchet mechanism
ConstructionReusable or single-use, according to model
DisassemblyOne-piece, detachable or modular
SterilisationAccording to supplied instructions
PackingIndividual, component set or complete system

Exact dimensions, materials, energy compatibility and sterilisation parameters require Bharat Surgical’s approved data.

Comparative Analysis

Mangeshikar-Type Manipulator vs Other Systems

Basic vs Advanced Mangeshikar-Type Manipulator

Basic configurationAdvanced configuration
Simplified uterine-positioning instrumentMulti-component hysterectomy system
May include handle, shaft and tenaculumIncludes several modular components
Limited tip or tube selectionMultiple intrauterine and tube sizes
May provide basic uterine movementDesigned for more comprehensive mobilisation
Easier assembly and reprocessingRequires detailed assembly and cleaning
Lower component countReplacement-part compatibility is critical

The quotation should state clearly which version is being supplied.

Mangeshikar-Type vs Cohen Manipulator

Mangeshikar-type manipulatorCohen manipulator
More comprehensive uterine-mobilisation designCompact diagnostic manipulator
May include cervical tenaculumCommonly uses small or large blunt tip
May include intrauterine elements and tubesMay include a dye-injection connection
Selected for operative laparoscopyCommon in diagnostic laparoscopy
Advanced models may support hysterectomy workflowsGenerally not a complete colpotomy system

Forceps Handle vs Ratchet Handle

Forceps Handle: Provides direct manual control of the cervical holding or uterine-positioning mechanism.

Ratchet Handle: Allows progressive locking at defined positions. It can maintain mechanical engagement without continuous hand pressure. Before selecting a ratchet model, verify ratchet-release action, number of locking positions, cervical jaw movement, ease of emergency release, cleaning access, and whether the ratchet controls holding, articulation or both.

Handle preference should be confirmed with the intended user.

Tube/Cup and Intrauterine-Element Selection

Tube or Cup: Advanced manipulators may include multiple tube or cup diameters to accommodate different anatomical requirements and provide fornix delineation. Selection should consider vaginal/cervical anatomy, procedure, and nearby energy instruments.

Intrauterine Element: Dimension-specific elements placed within the cavity. Verify uterine sounding depth, element length/diameter, tip shape, attachment method, and required movement before ordering.

Applications & Selection

Potential Applications and Selection Guidelines

Potential Applications

Depending on the exact model and approved intended use, the instrument may be selected for:

Total laparoscopic hysterectomy
Laparoscopic supracervical hysterectomy
Selected laparoscopic myomectomy procedures
Endometriosis procedures
Pelvic dissection
Diagnostic laparoscopy
Other procedures requiring uterine mobilisation

A claim that the device protects the bladder, ureters or rectum should only be used when supported by the exact system’s instructions and configuration.

How to Select the Correct Manipulator

Identify Procedure Requirements: Determine if a basic positioning model or an advanced hysterectomy system is required.

Select Handle Mechanism: Choose between forceps-style or ratchet handle.

Confirm Component Sizes: Verify intrauterine element sizes and tube/cup diameters.

Check Shaft & Length: Confirm shaft diameter and working/total lengths.

Verify Set vs Spare Parts: Specify complete set, individual components or replacement spares.

Review Reprocessing: Ensure the facility can dismantle and reprocess modular components correctly.

Reprocessing & Safety

Cleaning, Pre-Use Inspection and Safety Controls

Cleaning and Sterilisation

A modular reusable manipulator must be completely disassembled at its designated connection points before cleaning, where instructed. General precautions include:

Prevent blood and tissue residue from drying
Separate the handle, shaft, tenaculum, tube and intrauterine element
Open ratchets and locking mechanisms
Clean tenaculum jaws and hinges
Brush fixation grooves and sliding surfaces
Flush accessible channels and clean inside tubes/around insulating rings
Use compatible detergents, rinse thoroughly and dry internal/external surfaces
Inspect for retained residue, check alignment, reassemble matching parts
Conduct functional test and sterilise using validated cycle

Do not use original Bissinger reprocessing parameters for Bharat Surgical’s version unless it is the genuine product.

Common Ordering Mistakes

Using “Mangeshkar” as the correct product spelling
Ordering without identifying basic or advanced type
Assuming an instrument is original Bissinger
Ordering only the handle when a complete set is required
Confusing a tenaculum component with the complete manipulator
Not confirming intrauterine-element or tube/cup sizes
Assuming all components are interchangeable
Failing to confirm whether a sterilisation tray is included

Inspection Before Use

Inspect:

Handle operation and ratchet engagement/release
Main shaft alignment and cervical-tenaculum tips
Tenaculum-jaw alignment and intrauterine elements
Tube or cup surface, insulating ring, sliding fixation mechanism
Clasp and locking components, all attachment points
No cracks, corrosion or deformation, correct assembly, sterility status.

Safety Precautions & Clinical Review

Use only by trained gynaecological professionals.
Inspect every component before assembly; use only compatible parts.
Measure uterine depth; select appropriate element; do not force insertion.
Confirm secure engagement; avoid excessive tenaculum pressure or movement.
Review contraindications (pregnancy, IUD, infection, pathology).
Category risks include perforation, laceration, bleeding, infection.
B2B Supply

Supply Channels and Details Required for Quotation

Supply for Hospitals and Distributors

Bharat Surgical supports enquiries from:

Gynaecology hospitals
Multispeciality hospitals
Laparoscopy centres
Medical colleges
Government procurement departments
Surgical instrument dealers
Medical equipment distributors
Bulk institutional buyers
Export buyers

Availability, component selection, documentation, packing and delivery time depend on the selected system.

Why Buy from Bharat Surgical?

Basic and configurable uterine-manipulator options
Forceps and ratchet handle selections, subject to availability
Complete sets and replacement components
Institutional product-selection support
Dealer and distributor support
Bulk-order quotations
Reusable-instrument repair support where feasible
Documentation according to the supplied model
Packing and branding options subject to commercial terms

Bharat Surgical must clearly identify whether each product is original, compatible or its own Mangeshikar-type configuration.

Information Required for a Quotation

Please provide:

Intended surgical procedure
Basic or advanced configuration
Forceps or ratchet handle
Complete set or individual component
Cervical-tenaculum requirement
Intrauterine-element sizes
Tube or cup sizes
Shaft diameter
Working and total length
Insulating-ring requirement
Required quantity
Hospital, dealer or distributor enquiry
Delivery destination
Documentation requirement
Sterilisation-tray requirement
Packing or branding requirement, if applicable

If replacing a component, send photographs of the complete system, connection point and all catalogue markings.

Immediate Answers

Frequently Asked Questions

Technical, component, assembly and reprocessing answers for the Bharat Surgical Mangeshikar-Type Uterine Manipulator range.

The recognised spelling is Mangeshikar, named after Prof. Dr. Prashant Mangeshikar. “Mangeshkar” is a common catalogue and buyer-search misspelling.

It is a reusable mechanical system designed for uterine mobilisation and positioning during selected laparoscopic gynaecological procedures.

Depending on the model, it may be used during hysterectomy, myomectomy, pelvic dissection or other procedures requiring uterine positioning.

Advanced systems are designed for use in total laparoscopic hysterectomy. The capabilities of Bharat Surgical’s exact configuration must be verified.

Reusable models are available and require validated disassembly, cleaning, inspection and sterilisation.

A system may contain a handle, shaft, cervical tenaculum, intrauterine elements, fixation shaft, tubes, insulating rings and clasp.

No. It is one component unless the quoted product is a simplified tenaculum-style manipulator.

Both handle descriptions appear in Indian product ranges. Bharat Surgical should confirm its available versions.

The basic version has fewer components, while an advanced system may include multiple intrauterine elements, tubes and fixation parts.

Advanced systems may include several sizes. Exact Bharat Surgical availability must be confirmed.

Original advanced systems offer multiple tube diameters. Bharat Surgical should publish only the sizes it actually supplies.

No component should be mixed unless mechanical, dimensional and functional compatibility has been validated.

A Mangeshikar-type system should not be assumed to include chromopertubation unless an injection channel is specifically documented.

Only when the selected system contains a documented tube or cup intended for that function.

The existing Bharat Surgical listing states approximately 25 cm, but this must be rechecked before publication because other market models use different measurements.

Some Indian listings describe a 10 mm instrument, but the Mangeshikar system is generally positioned transvaginally. Shaft diameter must not be confused with a requirement for laparoscopic trocar insertion.

Potential risks include uterine perforation, cervical injury, bleeding, infection, component separation and tissue pressure injury.

Follow the validated reprocessing instructions supplied with the exact Bharat Surgical model.

Inspect the handle, tenaculum, shaft, intrauterine elements, tubes, insulating components and all locking mechanisms.

Replacement components may be supplied after the exact system, dimensions and connection style are confirmed.

Medical and Procurement Disclaimer: The original Mangeshikar Advanced+ system confirms a modular configuration with handle, shaft, cervical tenaculum, clasp, intrauterine elements, fixation shaft and multiple tubes. These specifications must not be attributed to Bharat Surgical’s model without verification (Bissinger Mangeshikar Advanced+, Bissinger gynaecology portfolio). Next Level 4 page: Marva Uterine Manipulator.

Request a Mangeshikar-Type Uterine Manipulator Quotation

Looking for a Mangeshikar-type uterine manipulator manufacturer or supplier in India? Share the required handle, intrauterine elements, tube sizes, total length, set configuration and quantity with Bharat Surgical. Our team can assist hospitals, dealers and distributors with complete systems and replacement-component identification.