Tintara Uterine Manipulator
Manufacturer and Supplier in India

The Tintara Uterine Manipulator from Bharat Surgical is a manually operated gynecological instrument designed to provide controlled uterine positioning during selected laparoscopic procedures. The instrument assists the surgical team in elevating, moving and stabilizing the uterus to improve access to pelvic anatomy.

Bharat Surgical lists its Tintara Uterine Manipulator as a stainless-steel instrument supplied in standard sizing with interchangeable tips. Exact tip lengths, articulation, fixation method, channel availability and included accessories should be confirmed through a component-wise technical quotation.

ISO 13485:2016 Certified
40+ Years Experience
Mumbai Warehousing
Bharat Surgical stainless-steel Tintara uterine manipulator with interchangeable tips
Overview

What Is a Tintara Uterine Manipulator?

A Tintara Uterine Manipulator is a transvaginal surgical instrument used to manipulate the uterus during selected diagnostic and operative gynecological procedures.

Depending on the supplied design, it may support:

Uterine elevation
Controlled anteversion
Controlled retroversion
Lateral uterine movement
Uterine stabilization
Improved exposure of the adnexa
Improved access to the anterior or posterior pelvis
Tissue presentation during selected laparoscopic procedures

Bharat Surgical confirms that its model is manufactured using stainless steel and includes interchangeable tips.

Origin of the Tintara-Type Design

The name “Tintara” is associated in medical literature with Professor Hatern Tintara, one of the developers of the Songkla Uterine Manipulator.

The published Songkla design used two stainless-steel rods, a pivoting head, a locking system and interchangeable obturators. A subsequent clinical trial compared the Songkla system with a Hulka controlling tenaculum for laparoscopic tubal ligation and reported greater lateral uterine movement with the Songkla device.

However, this published Songkla instrument should not automatically be treated as technically identical to Bharat Surgical’s commercial Tintara model. Dimensions, movement range, component design and intended use must be confirmed for the actual supplied instrument.

Variants & Components

Key Features and Possible Set Components

Key Features

Depending on the final configuration, the Tintara Uterine Manipulator may provide:

Manual uterine positioning
Stainless-steel construction
Reusable instrument design
Interchangeable intrauterine tips
Controlled anteversion
Controlled retroversion
Lateral movement
Mechanical articulation
Position-locking mechanism
Cervical fixation arrangement
Polished instrument surfaces
Disassembly for cleaning
Autoclave-compatible components, subject to the IFU
Standard or customized set configuration
Protective box or sterilization tray availability

Only stainless-steel material, standard sizing and interchangeable tips are currently confirmed on Bharat Surgical’s dedicated page. Other features must be verified against the supplied model.

Possible Set Components

A Tintara Uterine Manipulator set may contain:

Main operating handle
Instrument body or paired-rod frame
Pivoting or articulating head
Locking mechanism
Intrauterine obturator or tip
Additional interchangeable tips
Cervical fixation component
Connecting screws or locks
Cervical plate or stop, if included
Tenaculum-retaining component, if applicable
Storage or sterilization box

This is a procurement checklist, not a confirmed packing list. The final quotation must identify every supplied component.

Specifications

Product Specifications

Why Are Interchangeable Tips Required?

Interchangeable tips allow the surgical team to select an intrauterine component according to:

Uterine cavity depth
Uterine sounding measurement
Cervical condition
Uterine position
Patient anatomy
Planned surgical procedure
Required movement
Surgeon preference
Manufacturer’s instructions

Tip selection must consider both diameter and insertion length. A tip should never be selected only because it connects to the instrument handle.

Published Songkla Obturator Sizes

The original published Songkla Uterine Manipulator was described with a 4.7 mm obturator diameter and three standard obturator lengths of 6, 8 and 10 cm. It also incorporated a pivoting head and locking system.

These values provide historical technical context only. They must not be added to Bharat Surgical’s product specification table unless the client confirms that its Tintara model uses the same dimensions.

Product Specifications

SpecificationConfirmed or Configurable Detail
Product nameTintara Uterine Manipulator
Instrument categoryGynecology and laparoscopic instruments
General functionUterine positioning and manipulation
OperationManual
Main materialStainless steel
SizingStandard sizing listed
TipsInterchangeable tips included
UsageReusable model expected; confirm in quotation
ArticulationSubject to model confirmation
Fixation mechanismSubject to model confirmation
Cup systemNot confirmed on Bharat Surgical’s current listing
ChannelNot confirmed
Surface finishConfirm before publication
SterilizationObtain validated parameters from the supplied IFU
PackagingBox or specified packaging
BrandBharat Surgical
Country of originIndia
CustomizationSubject to technical feasibility

The website should not publish an exact length, diameter, movement angle, tip count or cup size until Bharat Surgical confirms these values.

Comparative Analysis

Tintara vs Other Uterine Manipulators

ManipulatorPrimary selection consideration
Tintara ManipulatorReusable pattern with interchangeable tips and controlled uterine movement
Cohen ManipulatorComparatively simple pattern for manipulation or selected injection applications
Mangeshikar-Type ManipulatorMulti-component design frequently considered for advanced laparoscopic hysterectomy
Marva ManipulatorAvailable in simple and special reusable configurations
Sukhadia ManipulatorPattern available with configurable colpotomy-related components
Storz-Type ManipulatorModular set with several tips and multiple cup sizes
V-Type ManipulatorAdjustable pattern with multiple cup options and single-channel configuration

Instrument selection should be based on function and verified specifications—not the product name alone.

Tintara vs V-Type Manipulator

Selection factorTintaraV-Type
Confirmed Bharat constructionStainless steelStainless steel
Tip arrangementInterchangeable tipsAtraumatic rounded tip listed
Cup optionsNot confirmedSmall, medium and large listed
ChannelNot confirmedSingle channel listed
ArticulationRequires confirmationAdjustable
Typical procurement focusTip lengths, articulation and fixationCup dimensions and channel function
Hysterectomy suitabilityMust be specifically confirmedDepends on selected configuration
Applications & Selection

Surgical Applications and How to Select the Correct Tintara Manipulator

Surgical Applications

Subject to model-specific approval, a Tintara Uterine Manipulator may be considered for:

Diagnostic laparoscopy
Laparoscopic tubal ligation
Adnexal surgery
Ovarian procedures
Fertility-related laparoscopic procedures
Pelvic adhesiolysis
Endometriosis procedures
Procedures requiring fallopian-tube exposure
Procedures requiring uterine elevation
Procedures requiring lateral uterine movement
Selected laparoscopic hysterectomy procedures
Other gynecological operations requiring uterine positioning

The published Songkla design was evaluated in procedures including tubal sterilization, adnexal surgery and hysterectomy. This evidence relates to the published device, not automatically to every commercial Tintara-pattern instrument.

Important Hysterectomy Suitability Note

Online supplier descriptions are inconsistent about using Tintara manipulators for total hysterectomy. Some market the instrument for total or supracervical laparoscopic hysterectomy, while one clinical review describes the Tintara type as suitable for multiple laparoscopic indications except total hysterectomy.

The original Songkla publication reported use in total laparoscopic and laparoscopic-assisted vaginal hysterectomy but also identified limitations, including the need for improved cervical retention and prevention of vaginal gas leakage.

Therefore, this page should not make an unrestricted claim that Bharat Surgical’s Tintara Manipulator is suitable for total laparoscopic hysterectomy.

Before using or purchasing the instrument for hysterectomy, confirm:

  • The exact intended use
  • Cervical fixation method
  • Vaginal sealing capability
  • Colpotomy-cup availability
  • Ability to maintain pneumoperitoneum
  • Manufacturer-approved procedure list
  • Model-specific warnings
  • Surgeon and hospital approval

How the Instrument Supports Pelvic Exposure

Controlled uterine movement may assist surgical exposure in several ways:

  • Anteversion may improve access to posterior structures.
  • Retroversion may improve exposure of the anterior pelvis.
  • Lateral movement may expose the opposite adnexa or pelvic sidewall.
  • Elevation may improve access to the cul-de-sac.
  • Stabilization can help maintain the selected uterine position.
  • Controlled movement may improve visualization of the fallopian tubes and ovaries.

The published comparative study found that the Songkla device provided greater lateral uterine movement and better fallopian-tube exposure than a Hulka controlling tenaculum in laparoscopic tubal-ligation cases. These findings should not be converted into claims of superiority for Bharat Surgical’s untested commercial model.

How to Select the Correct Tintara Manipulator

Confirm the intended procedure: State whether the instrument is required for diagnostic laparoscopy, tubal ligation, adnexal surgery, hysterectomy or another approved procedure.

Confirm the tip dimensions: Request:

  • Tip diameter
  • Tip length
  • Maximum insertion depth
  • Tip profile
  • Number of included tips
  • Connection type

Confirm the range of movement: Ask whether the instrument provides:

  • Anteversion
  • Retroversion
  • Bilateral movement
  • Elevation
  • Position locking

Do not use movement figures from the original Songkla paper unless they apply to Bharat Surgical’s exact model.

Confirm the fixation system: Establish how the device is retained relative to the cervix and whether a separate tenaculum is required.

Confirm cup availability: Ask whether a cervical, vaginal or colpotomy cup is included or compatible.

Confirm sealing capability: If required for laparoscopic hysterectomy, verify whether the set includes a validated vaginal sealing or occlusion component.

Confirm channel availability: Do not assume the instrument provides dye injection, suction or insufflation unless explicitly stated.

Reprocessing & Safety

Safety Considerations and Reprocessing

Safety Considerations

A Tintara Uterine Manipulator should be used only by qualified medical professionals trained in gynecological surgery. Important precautions include:

  • Assess the uterus and cervical canal before insertion.
  • Determine uterine cavity depth.
  • Select a suitable tip length.
  • Follow the natural uterine axis.
  • Do not use excessive insertion force.
  • Stop if unexpected resistance is encountered.
  • Do not exceed the instrument’s permitted movement.
  • Avoid excessive lateral pressure.
  • Confirm secure cervical fixation.
  • Monitor the instrument during manipulation.
  • Prevent prolonged tissue pressure.
  • Avoid unintended contact with active energy instruments.
  • Verify that all parts are present after removal.
  • Follow all contraindications in the supplied IFU.

Potential complications can include:

Uterine perforation
Cervical trauma
Vaginal injury
Bleeding
Infection
Pain or cramping
Tissue-pressure injury
Thermal injury
Instrument disconnection
Retained or separated components

Patient and Procedure Considerations

Suitability should be assessed carefully where there is:

  • Known or suspected pregnancy
  • Cervical stenosis
  • Uterine anomaly
  • Significant distortion of the uterine cavity
  • Active pelvic or genital infection
  • Unexplained uterine bleeding
  • Recent uterine perforation
  • Malignancy where manipulation may affect the operative plan
  • Severe uterine immobility
  • Inability to determine a safe insertion path

This is not a complete contraindication list. The supplied IFU and the surgeon’s clinical judgment take priority.

Use with Electrosurgical or Ultrasonic Energy

A stainless-steel uterine manipulator can conduct electrical energy and heat. Unless documented otherwise, it should not be considered insulated.

  • Maintain awareness of the manipulator’s position.
  • Avoid active-electrode contact with metal components.
  • Do not rely on a cervical plate or tip as an insulation barrier.
  • Inspect non-metallic components for damage.
  • Follow the energy-device manufacturer’s instructions.
  • Follow the manipulator’s model-specific warnings.
  • Remove any heat-damaged component from service.

Preoperative Inspection Checklist

Before use, trained personnel should:

  • Confirm that the instrument is suitable for the planned procedure.
  • Check that every required component is available.
  • Select the correct intrauterine tip.
  • Confirm tip length and intended insertion depth.
  • Inspect the tip for roughness, bending or damage.
  • Inspect the frame or shaft for alignment.
  • Test the pivoting or articulation mechanism.
  • Confirm that the selected position locks securely.
  • Check all screws and threaded connections.
  • Inspect the cervical fixation component.
  • Confirm that no component is loose.
  • Verify that the instrument has been correctly reprocessed.
  • Review the product-specific instructions.
  • Remove damaged or incomplete components from service.

Cleaning and Reprocessing

Follow Bharat Surgical’s validated instructions for the supplied model. A general reusable-instrument workflow may include:

  • Begin pre-cleaning promptly after use.
  • Prevent organic material from drying.
  • Disassemble all removable tips and connectors.
  • Open the articulation and locking mechanisms.
  • Rinse visible contamination.
  • Clean with a compatible enzymatic or neutral-pH detergent.
  • Brush joints, pivots, screws, threads and recessed areas.
  • Rinse thoroughly.
  • Dry all surfaces and internal spaces.
  • Inspect each component under adequate lighting.
  • Lubricate only where permitted.
  • Package the set in a validated sterilization system.
  • Sterilize using approved parameters.
  • Ensure complete drying before storage.

“Stainless steel” and “reusable” do not by themselves define a valid autoclave cycle.

Inspection After Reprocessing

Inspect for:

Residual organic material
Corrosion
Pitting
Discoloration
Bent rods or shafts
Damaged tips
Worn screws
Loose connections
Restricted articulation
Weak or unreliable locking
Rough edges
Cracks in non-metallic components
Missing tips
Moisture in joints
Incomplete set assembly

Remove the instrument from service if its mechanical integrity is uncertain.

B2B Supply

Available Supply Configurations and B2B Supply

Available Supply Configurations

Standard Tintara Uterine Manipulator: A reusable manual instrument supplied in Bharat Surgical’s standard configuration.

Tintara Manipulator with Interchangeable Tips: A set containing the main instrument and selected intrauterine tips.

Complete Tintara Manipulator Set: A complete working set containing the handle, shaft or frame, articulation system, tips, locks and specified accessories.

Basic Manipulation Set: A simplified configuration for uterine positioning without unrequired cups, channels or colpotomy components.

Replacement Tips: Compatible replacement tips may be supplied after the connection, dimensions and existing model are verified.

Customized Hospital Set: A set configured against a hospital specification, tender schedule, approved sample or surgeon requirement.

Common Procurement Mistakes

Avoid:

Assuming every Tintara instrument matches the original Songkla design
Publishing original Songkla dimensions as Bharat specifications
Ordering without tip lengths
Failing to confirm how many tips are included
Assuming that “standard size” is a sufficient specification
Assuming a cup is included
Assuming the instrument maintains pneumoperitoneum
Assuming it is suitable for total laparoscopic hysterectomy
Ordering without confirming cervical fixation
Assuming a dye-injection channel is present
Mixing tips from different manufacturers
Ordering replacement tips using photographs alone
Failing to obtain reprocessing instructions
Using generic supplier claims as clinical evidence
Failing to request a component-wise quotation

Information Required for a Quotation

Send Bharat Surgical:

Product name: Tintara Uterine Manipulator
Intended procedure
Complete set or replacement component
Required quantity
Tip diameters
Tip lengths
Number of interchangeable tips
Required range of movement
Locking requirement
Cervical fixation requirement
Tenaculum compatibility
Cup requirement
Colpotomy requirement
Vaginal sealing requirement
Channel or dye-injection requirement
Overall length requirement
Storage or sterilization box requirement
Existing product photograph or drawing
Required technical documents
Packaging requirements
Delivery destination
Domestic or export order
Tender specification, where applicable

Buyers Served

Bharat Surgical can receive enquiries from:

Hospitals
Gynecology departments
Laparoscopic surgery centres
Nursing homes
Medical colleges
Government institutions
Surgical-instrument distributors
Medical-equipment dealers
Tender suppliers
Importers
Exporters
Healthcare procurement companies

MOQ, component availability, price, production lead time and documentation should be reconfirmed for each order.

Why Source from Bharat Surgical?

Bharat Surgical is a Mumbai-based manufacturer and supplier of laparoscopic, gynecological, hysteroscopy, urology and general surgical instruments. Buyers can contact the company for:

Tintara Uterine Manipulators
Complete manipulator sets
Interchangeable-tip configurations
Replacement-tip enquiries
Reusable stainless-steel instruments
Hospital and institutional supply
Dealer and distributor orders
Bulk procurement
Tender requirements
Export enquiries
Customized configurations
Related gynecological instruments

Bharat Surgical includes the Tintara Uterine Manipulator in its current surgical-instrument catalogue.

Immediate Answers

Frequently Asked Questions

Technical, sizing, injection and reprocessing answers for the Bharat Surgical Tintara Uterine Manipulator range.

It is a gynecological instrument used to position and mobilize the uterus during selected laparoscopic procedures.

The company’s current product page specifies stainless steel.

Yes. Interchangeable tips are listed as part of Bharat Surgical’s configuration.

The public listing does not state the number. Buyers should request a component-wise packing list.

Bharat Surgical has not published the individual diameters or lengths. These should be confirmed before ordering.

Bharat Surgical’s stainless-steel model is intended as a reusable pattern, but the supplied IFU should confirm reprocessing and reuse requirements.

The names are historically related through Professor Hatern Tintara, but Bharat Surgical’s commercial model should not be considered technically identical without confirmation.

Tintara-pattern instruments are intended for controlled uterine positioning. The exact movements and range of Bharat Surgical’s model must be confirmed.

The published Songkla design provides lateral movement. The available movement of Bharat Surgical’s exact model should be verified.

The Songkla design was clinically studied for laparoscopic tubal ligation. Suitability of Bharat Surgical’s version depends on its approved intended use.

A uterine manipulator may support adnexal exposure, but the surgeon must confirm that the supplied Tintara model is appropriate.

This must be confirmed for the exact model. Published and commercial descriptions are inconsistent, and some configurations may lack adequate cervical fixation or vaginal sealing.

A cup is not confirmed on Bharat Surgical’s current Tintara product listing. It should be requested separately if required and compatible.

Not unless the supplied system includes a compatible and validated vaginal sealing component.

A dye-injection channel is not confirmed. Buyers requiring chromopertubation should request a model specifically designed for injection.

Some Tintara or Songkla-type designs use a cervical tenaculum or retaining hook. The fixation method of Bharat Surgical’s model must be confirmed.

The sterilization method and validated cycle must be obtained from the supplied instructions. Do not rely only on the stainless-steel description.

Compatibility must never be assumed. Diameter, screw design, connection geometry and locking method may differ.

Inspect the tips, rods or shaft, pivot, locks, screws, fixation component, surface condition and sterilization status.

Potential risks include uterine perforation, cervical or vaginal injury, bleeding, infection, tissue-pressure injury and component separation.

Provide the intended procedure, quantity, required tip sizes, movement requirement, fixation method, cup or channel requirement and delivery destination.

Bharat Surgical manufactures and supplies Tintara Uterine Manipulators from Mumbai, India, subject to current configuration and availability.

Medical and Procurement Disclaimer: Add price, availability, tip dimensions, clinical indications, ratings, certifications and regulatory claims only after verification through current Bharat Surgical documentation. Next Level 4 page: Hysteroscopy Monopolar Electrode.

Request a Quote for Tintara Uterine Manipulator

Contact Bharat Surgical for: Standard Tintara Uterine Manipulators, Sets with interchangeable tips, Complete set enquiries, Replacement-tip requirements, Hospital procurement, Distributor and dealer supply, Bulk orders, Export enquiries, Tender requirements, Customized configurations.