The Sukhadia Uterine Manipulator by Bharat Surgical is a reusable laparoscopic instrument designed to support controlled uterine positioning during hysterectomy and other selected gynecological procedures. The instrument helps the surgical team mobilize and stabilize the uterus to improve operative exposure during minimally invasive surgery.
Manufactured using stainless steel and medical-grade components, the Sukhadia Manipulator can be supplied with colpotomy components according to the required configuration. Bharat Surgical’s current product listing describes the instrument as reusable, with retroversion articulation, an insufflation port, a trumpet-type tip and a small cup; these specifications should be reconfirmed when requesting a quotation. Bharat Surgical product listing
Looking for a Sukhadia Uterine Manipulator manufacturer in India? Contact Bharat Surgical for available configurations, component details, commercial quantities and export enquiries.
A Sukhadia Uterine Manipulator is a transvaginal gynecological instrument used to position and mobilize the uterus during laparoscopic surgery. Depending on the selected configuration, the surgeon may use it to:
Bharat Surgical identifies its Sukhadia Manipulator as a stainless-steel instrument supplied with colpotomizers and intended for laparoscopic hysterectomy, including total and supracervical procedures. Bharat Surgical Sukhadia Manipulator
The exact clinical application must always be based on the supplied model, component configuration, approved instructions for use and the operating surgeon’s judgment.
| Specification | Available or Configurable Detail |
|---|---|
| Product name | Sukhadia Uterine Manipulator |
| Alternate search spelling | Sukhadiya Uterine Manipulator |
| Product category | Gynecology and laparoscopic instruments |
| Intended general function | Uterine positioning and manipulation |
| Primary construction | Stainless steel with medical-grade components |
| Usage | Reusable |
| Articulation | Retroversion configuration listed |
| Tip type | Trumpet-type tip listed |
| Cup | Small cup listed; other options subject to confirmation |
| Channel | Insufflation port listed |
| Colpotomy component | Included/configurable according to set |
| Surface finish | Polished |
| Sterilization | Autoclavable when permitted by the supplied IFU |
| Application | Selected gynecological and laparoscopic procedures |
| Brand | Bharat Surgical |
| Country of origin | India |
| Packaging | Protective box or specified packaging |
| Customization | Subject to technical feasibility and order quantity |
All dimensions, cup sizes, tip lengths, materials, channel connections and sterilization parameters must be verified against the final quotation and product instructions.
A Sukhadia Manipulator set may contain:
The presence of any component should not be assumed from the product-family name alone. Bharat Surgical should provide the final component list with the commercial offer.
Subject to the exact configuration and instructions for use, a Sukhadia Uterine Manipulator may be considered for:
Listing a procedure does not mean every Sukhadia configuration is suitable for it. The surgeon must assess the patient, procedure and supplied device.
Controlled uterine mobilization can change the relationship between the uterus and surrounding pelvic structures, helping the team obtain a clearer working plane:
These functions depend on correct assembly, suitable sizing, patient anatomy and proper surgical technique.
| Instrument type | Typical distinguishing consideration |
|---|---|
| Sukhadia Manipulator | Reusable Indian trade-pattern design with configurable cup, tip and colpotomy components |
| Cohen Manipulator | Often selected for comparatively simple uterine manipulation or injection applications |
| Mangeshikar-Type Manipulator | Multi-component design commonly considered for laparoscopic hysterectomy |
| Marva Manipulator | Available in simple and special configurations from Indian instrument suppliers |
| Storz-Type Manipulator | Pattern-based configuration requiring careful compatibility and component verification |
| V-Type Manipulator | Recognized by its characteristic frame or handle arrangement |
| Tintara Manipulator | Alternative reusable pattern selected according to surgeon preference |
Product-family names are not interchangeable technical standards. Instruments with similar names from different manufacturers may have different dimensions, mechanisms and accessories.
Before requesting a quotation, confirm:
Before use, inspect shaft alignment, tips, cups, locking mechanisms, seals, valves, ports and channel patency. Ensure the instrument is sterile and correctly assembled.
Principal Risks: Potential complications include uterine perforation, cervical/vaginal trauma, bleeding, infection, pain/cramping, tissue damage from excessive pressure, incorrect insertion depth, component separation, and thermal injury if energy devices act close to unsuitable components.
Never use excessive force to overcome cervical resistance. Insertion and operation must be performed solely by trained medical professionals.
Promptly clean after use, prevent blood/tissue drying, disassemble removable parts, rinse, clean with enzymatic/neutral detergent, brush joints/threads/recessed areas, flush channels, rinse, dry thoroughly, inspect, reassemble, package and sterilize using validated cycles. Do not assume polymer parts tolerate the same cycle as stainless steel.
Bharat Surgical supplies Sukhadia uterine manipulator sets, configurable components, stainless-steel reusable instruments, and tender support to hospitals, distributors, and export buyers.
When requesting a quotation, please provide:
Technical, component, configuration and reprocessing answers for the Bharat Surgical Sukhadia Uterine Manipulator range.
It is a gynecological instrument used to position, mobilize and stabilize the uterus during selected laparoscopic procedures.
It is primarily considered for uterine manipulation during laparoscopic gynecological surgery, including selected hysterectomy procedures.
Bharat Surgical’s listed model is reusable. It must be cleaned, inspected and sterilized according to the supplied instructions.
The Bharat Surgical product listing specifies stainless steel, with medical-grade components used according to the selected configuration.
Bharat Surgical’s current product page states that colpotomizers are included. Buyers should request the exact quantity, sizes and component list in writing.
A small cup is listed for one Bharat Surgical configuration. Cup availability and dimensions must be confirmed during ordering.
An insufflation port is listed for the current configuration. Its connector, intended function and operating instructions should be confirmed before use.
An insufflation port does not automatically establish compatibility with dye injection. Request written confirmation if chromopertubation or fluid injection is required.
Bharat Surgical lists retroversion articulation for its Sukhadia model. The exact movement range is not published and should be confirmed if critical.
The product is marketed for laparoscopic hysterectomy. Final suitability depends on the supplied configuration, patient anatomy, procedure and surgeon assessment.
Bharat Surgical lists supracervical hysterectomy among the intended applications. The required accessories may differ from those used for total hysterectomy.
The listed reusable instrument is described as autoclavable. The validated temperature, exposure time and drying cycle must come from the product-specific instructions.
Different specifications may be available on request. Obtain the available diameters and compatible product references before ordering.
Replacement components may be supplied, but compatibility must be verified using the original model, dimensions and connection design.
Both spellings appear in the Indian surgical-instrument market. Bharat Surgical’s website uses “Sukhadia Manipulator” as the product title and “Sukhadiya Type” in another listing.
No. They are different uterine-manipulator patterns and may use different handles, cups, tips and locking mechanisms.
Cross-brand compatibility should never be assumed. Small differences in threads, shafts, locks and cup connections can affect secure assembly.
Check cleanliness, sterilization status, shaft alignment, cup integrity, tip condition, locking function, articulation, channel patency and secure assembly.
Potential risks include uterine perforation, cervical or vaginal injury, bleeding, infection, excessive tissue pressure and component separation.
Send Bharat Surgical the required configuration, cup and tip sizes, component list, quantity, delivery destination and any tender or regulatory requirements.
Medical and Procurement Disclaimer: All dimensions, cup sizes, tip lengths, materials, channel connections and sterilization parameters must be verified against the final quotation and product instructions. Next Level 4 page: Storz Type Uterine Manipulator.
Contact Bharat Surgical for complete Sukhadia Uterine Manipulator sets, configurable instrument components, bulk orders, hospital procurement and export enquiries.