Sukhadia Uterine Manipulator

The Sukhadia Uterine Manipulator by Bharat Surgical is a reusable laparoscopic instrument designed to support controlled uterine positioning during hysterectomy and other selected gynecological procedures. The instrument helps the surgical team mobilize and stabilize the uterus to improve operative exposure during minimally invasive surgery.

Manufactured using stainless steel and medical-grade components, the Sukhadia Manipulator can be supplied with colpotomy components according to the required configuration. Bharat Surgical’s current product listing describes the instrument as reusable, with retroversion articulation, an insufflation port, a trumpet-type tip and a small cup; these specifications should be reconfirmed when requesting a quotation. Bharat Surgical product listing

Looking for a Sukhadia Uterine Manipulator manufacturer in India? Contact Bharat Surgical for available configurations, component details, commercial quantities and export enquiries.

ISO 13485:2016 Certified
40+ Years Experience
Mumbai Warehousing
Sukhadia Uterine Manipulator surgical instrument on a clean clinical blue background
Overview

What Is a Sukhadia Uterine Manipulator?

A Sukhadia Uterine Manipulator is a transvaginal gynecological instrument used to position and mobilize the uterus during laparoscopic surgery. Depending on the selected configuration, the surgeon may use it to:

Elevate or depress the uterus
Produce controlled anteversion or retroversion
Move the uterus laterally
Stabilize the uterus during dissection
Improve exposure of pelvic structures
Help identify the vaginal fornices
Support colpotomy during laparoscopic hysterectomy
Assist with maintenance of the operative field when an appropriate sealing component is included

Bharat Surgical identifies its Sukhadia Manipulator as a stainless-steel instrument supplied with colpotomizers and intended for laparoscopic hysterectomy, including total and supracervical procedures. Bharat Surgical Sukhadia Manipulator

The exact clinical application must always be based on the supplied model, component configuration, approved instructions for use and the operating surgeon’s judgment.

Sukhadia Manipulator Features

Depending on the ordered model, the Sukhadia Uterine Manipulator may offer:

Reusable instrument construction
Stainless-steel main components
Controlled uterine positioning
Retroversion movement
Ergonomic operating handle
Secure mechanical locking
Interchangeable or configurable components
Trumpet-type intrauterine tip
Cervical or vaginal cup
Colpotomy component
Insufflation or injection channel
Polished surfaces for cleaning and handling
Disassembly for reprocessing, where applicable
Configurations for hospital and surgical-centre requirements
Storage or sterilization tray availability on request

Features and included components can differ between production batches, models and customized sets. Buyers should obtain a component-wise quotation before ordering.

Specifications

Product Specifications and Possible Set Components

Product Specifications

SpecificationAvailable or Configurable Detail
Product nameSukhadia Uterine Manipulator
Alternate search spellingSukhadiya Uterine Manipulator
Product categoryGynecology and laparoscopic instruments
Intended general functionUterine positioning and manipulation
Primary constructionStainless steel with medical-grade components
UsageReusable
ArticulationRetroversion configuration listed
Tip typeTrumpet-type tip listed
CupSmall cup listed; other options subject to confirmation
ChannelInsufflation port listed
Colpotomy componentIncluded/configurable according to set
Surface finishPolished
SterilizationAutoclavable when permitted by the supplied IFU
ApplicationSelected gynecological and laparoscopic procedures
BrandBharat Surgical
Country of originIndia
PackagingProtective box or specified packaging
CustomizationSubject to technical feasibility and order quantity

All dimensions, cup sizes, tip lengths, materials, channel connections and sterilization parameters must be verified against the final quotation and product instructions.

Possible Set Components

A Sukhadia Manipulator set may contain:

Main operating handle
Manipulator shaft
Intrauterine tip or trumpet
Cervical stop
Vaginal or colpotomy cup
Colpotomizer
Locking and adjustment components
Insufflation or injection connection
Sealing component, if specified
Assembly accessories
Storage or sterilization tray, if ordered

The presence of any component should not be assumed from the product-family name alone. Bharat Surgical should provide the final component list with the commercial offer.

Available Supply Configurations

Complete Sukhadia Manipulator Set: Contains handle, shaft, required uterine component and specified cup or colpotomy accessories.
Basic Sukhadia Manipulator: Simplified configuration for positioning without extra colpotomy/sealing parts.
Sukhadia Manipulator with Colpotomy Cups: Includes requested cervical or vaginal cup sizes.
Sukhadia Manipulator with Insufflation Port: Incorporates compatible channel/port (confirm medium and pressure).
Replacement Components & Custom Sets: Tips, cups, sealing parts or custom hospital tender configurations.
Applications

Surgical Applications and How It Supports Surgery

Surgical Applications

Subject to the exact configuration and instructions for use, a Sukhadia Uterine Manipulator may be considered for:

Total laparoscopic hysterectomy
Laparoscopic-assisted vaginal hysterectomy
Selected supracervical hysterectomy procedures
Gynecological laparoscopy
Pelvic dissection requiring uterine mobilization
Endometriosis procedures
Adnexal surgery requiring improved pelvic exposure
Selected fertility-related laparoscopic procedures
Procedures requiring controlled anteversion or retroversion
Procedures requiring cervical or vaginal fornix delineation

Listing a procedure does not mean every Sukhadia configuration is suitable for it. The surgeon must assess the patient, procedure and supplied device.

How the Instrument Supports Laparoscopic Surgery

Controlled uterine mobilization can change the relationship between the uterus and surrounding pelvic structures, helping the team obtain a clearer working plane:

Uterine elevation may improve access to the posterior pelvis.
Lateral movement may expose the opposite pelvic sidewall.
Anteversion or retroversion may assist visualization of anterior or posterior anatomy.
A properly selected cup may help delineate the vaginal fornices.
A compatible sealing component may support pneumoperitoneum during parts of a hysterectomy.

These functions depend on correct assembly, suitable sizing, patient anatomy and proper surgical technique.

Comparisons

Sukhadia vs Other Uterine Manipulators & Selection Guide

Sukhadia vs Other Uterine Manipulators

Instrument typeTypical distinguishing consideration
Sukhadia ManipulatorReusable Indian trade-pattern design with configurable cup, tip and colpotomy components
Cohen ManipulatorOften selected for comparatively simple uterine manipulation or injection applications
Mangeshikar-Type ManipulatorMulti-component design commonly considered for laparoscopic hysterectomy
Marva ManipulatorAvailable in simple and special configurations from Indian instrument suppliers
Storz-Type ManipulatorPattern-based configuration requiring careful compatibility and component verification
V-Type ManipulatorRecognized by its characteristic frame or handle arrangement
Tintara ManipulatorAlternative reusable pattern selected according to surgeon preference

Product-family names are not interchangeable technical standards. Instruments with similar names from different manufacturers may have different dimensions, mechanisms and accessories.

How to Select the Correct Configuration

Before requesting a quotation, confirm:

1. Surgical procedure: Specify general manipulation, laparoscopic hysterectomy, colpotomy support or other approved use.
2. Complete set or component: State if you need a full working set, replacement cup, tip, shaft or handle.
3. Tip & Cup requirements: Confirm preferred tip style/length and cervical/vaginal cup diameters.
4. Colpotomy & Channels: Clarify if a colpotomizer, insufflation port or dye-injection facility is needed.
5. Reprocessing & Compatibility: Share cleaning/sterilization processes and provide existing references/photos for spare parts.
Safety & Supply

Preoperative Checks, Safety, Reprocessing and B2B Supply

Preoperative Checks & Safety Considerations

Before use, inspect shaft alignment, tips, cups, locking mechanisms, seals, valves, ports and channel patency. Ensure the instrument is sterile and correctly assembled.

Principal Risks: Potential complications include uterine perforation, cervical/vaginal trauma, bleeding, infection, pain/cramping, tissue damage from excessive pressure, incorrect insertion depth, component separation, and thermal injury if energy devices act close to unsuitable components.

Never use excessive force to overcome cervical resistance. Insertion and operation must be performed solely by trained medical professionals.

Cleaning, Disinfection and Sterilization

Promptly clean after use, prevent blood/tissue drying, disassemble removable parts, rinse, clean with enzymatic/neutral detergent, brush joints/threads/recessed areas, flush channels, rinse, dry thoroughly, inspect, reassemble, package and sterilize using validated cycles. Do not assume polymer parts tolerate the same cycle as stainless steel.

B2B Supply & Information Required for Quotation

Bharat Surgical supplies Sukhadia uterine manipulator sets, configurable components, stainless-steel reusable instruments, and tender support to hospitals, distributors, and export buyers.

When requesting a quotation, please provide:

Product name: Sukhadia Uterine Manipulator
Complete set or replacement component
Intended surgical procedure
Required quantity
Tip style and size, intrauterine working length, cup diameters
Colpotomizer, insufflation port or injection channel requirements
Preferred handle or articulation
Sterilization tray requirement
Delivery destination and regulatory/tender documentation needs
Immediate Answers

Frequently Asked Questions

Technical, component, configuration and reprocessing answers for the Bharat Surgical Sukhadia Uterine Manipulator range.

It is a gynecological instrument used to position, mobilize and stabilize the uterus during selected laparoscopic procedures.

It is primarily considered for uterine manipulation during laparoscopic gynecological surgery, including selected hysterectomy procedures.

Bharat Surgical’s listed model is reusable. It must be cleaned, inspected and sterilized according to the supplied instructions.

The Bharat Surgical product listing specifies stainless steel, with medical-grade components used according to the selected configuration.

Bharat Surgical’s current product page states that colpotomizers are included. Buyers should request the exact quantity, sizes and component list in writing.

A small cup is listed for one Bharat Surgical configuration. Cup availability and dimensions must be confirmed during ordering.

An insufflation port is listed for the current configuration. Its connector, intended function and operating instructions should be confirmed before use.

An insufflation port does not automatically establish compatibility with dye injection. Request written confirmation if chromopertubation or fluid injection is required.

Bharat Surgical lists retroversion articulation for its Sukhadia model. The exact movement range is not published and should be confirmed if critical.

The product is marketed for laparoscopic hysterectomy. Final suitability depends on the supplied configuration, patient anatomy, procedure and surgeon assessment.

Bharat Surgical lists supracervical hysterectomy among the intended applications. The required accessories may differ from those used for total hysterectomy.

The listed reusable instrument is described as autoclavable. The validated temperature, exposure time and drying cycle must come from the product-specific instructions.

Different specifications may be available on request. Obtain the available diameters and compatible product references before ordering.

Replacement components may be supplied, but compatibility must be verified using the original model, dimensions and connection design.

Both spellings appear in the Indian surgical-instrument market. Bharat Surgical’s website uses “Sukhadia Manipulator” as the product title and “Sukhadiya Type” in another listing.

No. They are different uterine-manipulator patterns and may use different handles, cups, tips and locking mechanisms.

Cross-brand compatibility should never be assumed. Small differences in threads, shafts, locks and cup connections can affect secure assembly.

Check cleanliness, sterilization status, shaft alignment, cup integrity, tip condition, locking function, articulation, channel patency and secure assembly.

Potential risks include uterine perforation, cervical or vaginal injury, bleeding, infection, excessive tissue pressure and component separation.

Send Bharat Surgical the required configuration, cup and tip sizes, component list, quantity, delivery destination and any tender or regulatory requirements.

Medical and Procurement Disclaimer: All dimensions, cup sizes, tip lengths, materials, channel connections and sterilization parameters must be verified against the final quotation and product instructions. Next Level 4 page: Storz Type Uterine Manipulator.

Request a Quote for Sukhadia Uterine Manipulator

Contact Bharat Surgical for complete Sukhadia Uterine Manipulator sets, configurable instrument components, bulk orders, hospital procurement and export enquiries.