Laparoscopic Aspiration Needle
Manufacturer in India

Bharat Surgical manufactures and supplies reusable laparoscopic aspiration needles with stainless-steel construction and a tubing connector for hospital, gynecology and laparoscopic instrument requirements. A published model is listed with a 16 G needle, 5 mm shaft diameter and 120 mm working length. Hospitals, surgical centres, medical colleges, dealers and distributors can request exact needle-tip specifications, shaft dimensions, tubing compatibility, reprocessing documentation and current prices.

ISO 13485:2016 Certified
40+ Years Experience
Mumbai Warehousing
Laparoscopic Aspiration Needle
Schematic representation showing the 16 G beveled aspiration tip (red), the 5 mm shaft, and the proximal luer connector for tubing.
Product Overview

What Is a Laparoscopic Aspiration Needle?

A laparoscopic aspiration needle is a long-shaft instrument designed to provide a controlled fluid pathway during selected minimally invasive procedures. It commonly incorporates a needle tip, tubular shaft, handle or connector assembly and a connection for compatible aspiration tubing.

The correct product must be selected according to its intended application, needle gauge, shaft diameter, working length, tip configuration, tubing connection and reusable or single-use status.

Clinical Notice & Safety Guidance

This page supports product evaluation and procurement. It does not provide instructions for performing aspiration or any other surgical procedure.

BSC Product Range

Bharat Surgical Laparoscopic Aspiration Needle Range

Bharat Surgical’s current listings identify reusable stainless-steel laparoscopic aspiration needle configurations for gynecological and general laparoscopic requirements.

Published configuration Specification
Needle gauge 16 G
Shaft diameter 5 mm on the laparoscopic-instrument listing
Working length 120 mm
Channel connection Tubing connector
Material Stainless steel
Finish Polished
Usage type Reusable
Sterilization description Autoclavable
Application Laparoscopic and hospital use
Brand Bharat Surgical
Country of origin India

These specifications are drawn from Bharat Surgical’s laparoscopic aspiration needle listing. A separate gynecology listing shows a 10 mm diameter, while the laparoscopic range shows 5 mm. Buyers must therefore confirm the correct diameter using the current product code or technical drawing.

Specifications

Published Technical Specifications

Specification Published information
Product name Laparoscopic Aspiration Needle
Needle gauge 16 G
Working length 120 mm
Published shaft diameter 5 mm
Connection Tubing connector
Material Stainless steel
Finish Polished
Reusability Reusable
Sterilization Autoclavable
Sterile status Inconsistently listed
Application Laparoscopic aspiration
Brand Bharat Surgical
Origin Made in India
Specifications

Important Specification Clarification

Some current marketplace fields appear inconsistent:

The laparoscopic listing states a 5 mm diameter, while the gynecology listing states 10 mm.
“Needle type” is shown as Veress in certain fields, even though the product is separately described as an aspiration needle.
Sterility is shown as “sterile” in one listing, while the instrument is also described as reusable and autoclavable.
Exact stainless-steel grade is not consistently stated.

Procurement Advisory

These fields should not be copied directly into a hospital BOQ. Request a current technical sheet confirming the instrument’s classification, diameter, gauge, working length, sterile supply status and material grade.

System Components

Main Components of an Aspiration Needle

A reusable laparoscopic aspiration needle may include:

Distal needle tip

Internal aspiration lumen

Stainless-steel shaft

Handle or connector housing

Tubing connection

Size and product markings

Cleaning access, where provided

Protective tip arrangement for storage and reprocessing

Procurement Notice: The exact assembly and whether components are detachable must be confirmed for the selected model.

Selection Guide

How to Select a Laparoscopic Aspiration Needle

Before requesting a quotation, specify:

Intended surgical department
Required application
Needle gauge
Shaft diameter
Working length
Distal-tip profile
Lumen diameter
Trocar or cannula size
Tubing connector type
Aspiration tubing dimensions
Required suction source compatibility
Reusable or single-use requirement
Sterile or non-sterile supply
CSSD reprocessing method
Required quantity
Delivery location

Procurement Notice: Clinical suitability and procedural selection must be determined by qualified medical personnel.

Product Comparison

5 mm vs 10 mm Aspiration Needle

Selection factor 5 mm configuration 10 mm configuration
Published status Listed in the laparoscopic instrument range Listed on a separate gynecology page
Working length 120 mm published 120 mm shown on the separate listing
Needle gauge 16 G published 16 G shown on the separate listing
Access requirement Compatible 5 mm or larger port, subject to actual diameter Compatible 10 mm or larger port, subject to actual diameter
Tubing connector Listed Listed
Current availability Confirm Confirm
Final selection Based on product code and verified dimensions Based on product code and verified dimensions

Because the online specifications conflict, the website should not present both diameters as confirmed standard variants unless Bharat Surgical verifies them.

Product Comparison

Aspiration Needle vs Veress Needle

An aspiration needle and a Veress needle should not be treated as the same product merely because one marketplace field uses the term “Veress.”

Feature Aspiration Needle Veress Needle
Main product function Provides a pathway for aspiration through compatible tubing Used as an access needle for creating pneumoperitoneum according to approved technique
Connection Aspiration or tubing connector Insufflation connector
Fluid or gas pathway Intended for aspiration Intended for insufflation
Distal construction Model-specific aspiration tip Typically incorporates a spring-loaded blunt stylet
Selection basis Gauge, lumen, shaft, tubing and application Length, diameter, valve, stylet and insufflator compatibility
Interchangeability Should not be assumed Should not be assumed

Bharat Surgical’s aspiration and Veress needles should have separate product codes, technical sheets and website pages.

Product Comparison

Aspiration Needle vs Suction–Irrigation Instrument

Feature Aspiration Needle Suction–Irrigation Instrument
Distal profile Needle tip Cannula or probe
Published connection Tubing connector Suction and/or irrigation connection
Main pathway Aspiration lumen Larger suction or irrigation channel
Typical shaft profile Narrow needle and shaft assembly Cannula-style instrument
Flow control Model-specific Trumpet, thumb-control or other valve may be provided
Procurement category Needle instrument Suction–irrigation instrument
Interchangeability Not a general substitute Not a general substitute

The instrument should be chosen according to the required function and surgeon-approved clinical protocol.

Aspiration Needle Details

Needle Gauge, Shaft Diameter and Lumen Size

These three measurements describe different parts of the instrument:

Needle gauge

Relates to the needle or internal cannula specification.

Shaft diameter

Relates to the outer laparoscopic portion that must pass through the trocar.

Lumen diameter

Affects the internal fluid pathway and connector matching.

A published 16 G needle with a 5 mm shaft does not mean the complete fluid channel is 5 mm. Hospitals should request a dimensioned technical drawing when exact lumen and flow requirements matter.

Aspiration Needle Details

Trocar Compatibility

Before approving the product, verify:

Instrument’s maximum external diameter
Trocar’s internal working diameter
Valve and seal design
Tip protection during passage
Working length
Handle clearance
Tubing movement near the access port
Reducer requirement
Compatibility under the hospital’s approved setup

Do not rely only on a “5 mm” or “10 mm” product description.

Aspiration Needle Details

Tubing and Connector Compatibility

The published model includes a tubing connector, but its precise interface is not specified. Buyers should confirm:

Connector type
Connector outer diameter
Compatible tubing internal diameter
Luer, tapered or model-specific connection
Whether tubing is supplied
Whether an adapter is required
Connection-retention method
Reusable or disposable tubing requirement
Compatibility with the hospital’s approved suction system

Do not assume that any available suction tubing will fit the instrument securely.

Product Comparison

Reusable vs Single-Use Aspiration Needle

Selection factor Reusable needle Single-use needle
Published Bharat Surgical model Reusable Not confirmed on current listing
Reprocessing Required after each use Normally not reprocessed
Inspection Required before and after reprocessing Packaging and integrity checked before use
Documentation IFU and validated cleaning process required Sterility and disposal documentation required
Procurement cost Instrument plus reprocessing cost Per-procedure purchase and disposal cost
Selection basis Hospital policy, intended use and validated workflow Hospital policy and model availability

Bharat Surgical’s published aspiration needle is reusable, but its exact reuse limitations must be confirmed from the current IFU.

Cleaning & Care

Inspection Before Reprocessing and Use

Reprocessing Care Guidelines

Inspect the complete instrument for:

Any instrument with a damaged tip, blocked lumen, loose connector, visible corrosion or leakage should be removed from service and assessed according to hospital policy.

Reprocessing Checklist
Bent or deformed needle tip
Blunt, damaged or burred distal point
Blocked lumen
Cracks or dents in the shaft
Loose handle or connector
Damaged tubing connection
Corrosion, pitting or staining
Retained material inside the lumen
Poor alignment
Damaged identification markings
Leakage at joints or connector interfaces
Missing components
Cleaning & Care

Cleaning and Sterilization Considerations

Reprocessing Care Guidelines

A reusable aspiration needle contains a narrow internal lumen that must be cleaned and inspected according to validated instructions.

General considerations include:

The term “autoclavable” alone is not a complete reprocessing instruction. Hospitals require validated temperature, pressure, exposure, drying and packaging parameters.

Reprocessing Checklist
Prevent residue from drying within the lumen.
Use the cleaning method specified in the product IFU.
Flush and brush the channel only with compatible equipment.
Do not use oversized brushes that may damage the lumen.
Confirm that the distal opening is unobstructed.
Inspect both the needle and tubing connector.
Rinse according to the validated CSSD procedure.
Dry the internal channel completely.
Protect the distal tip during handling and packaging.
Use only the approved sterilization method.
Record reprocessing cycles where required by hospital policy.
B2B Supply Channels

For Hospitals and Surgical Centres

Bharat Surgical can support enquiries for:

Laparoscopic aspiration instrument requirements
Gynecology instrument sets
General laparoscopic instrument sets
Replacement of worn or blocked aspiration needles
New OT procurement
Departmental standardization
Rate-contract and tender requirements
Medical college and training-centre procurement
Multi-hospital bulk requirements
Technical samples, subject to availability

Before technical approval, hospitals should request the current product code, dimensions, IFU, connector details and sterile-supply declaration.

B2B Supply Channels

For Dealers and Distributors

Dealers, importers and distributors may enquire about:

Dealer and wholesale pricing
Bulk quantity quotations
Mixed laparoscopic instrument orders
Product photographs and catalogue data
Current minimum order quantity
Export packaging
OEM or private-label availability, where offered
Commercial lead times
Territory or distribution discussions
Shipping and documentation

Commercial terms and product availability should be confirmed in writing.

B2B Supply Channels

Suggested Hospital BOQ Description

Suggested Tender/BOQ Text Template Copy for procurement document

"Reusable laparoscopic aspiration needle, 16 G needle specification, [5 mm/confirmed diameter] shaft, 120 mm working length, stainless-steel construction, polished finish, compatible tubing connector, suitable for validated hospital reprocessing, supplied with product-specific IFU and technical documentation."

The final BOQ must use the verified diameter, connector type, lumen specification, sterile status and material grade for the selected product code.

BSC Product Range

Related Laparoscopic Products

Selection Guide

Why Choose Bharat Surgical?

Reusable laparoscopic aspiration needle
Stainless-steel construction
Published 16 G needle specification
Published 120 mm working length
Tubing-connector configuration
Hospital and institutional supply support
Dealer and bulk-order enquiries
Wider laparoscopic and gynecology instrument range
Indian manufacturing and supply base

All technical details should be confirmed against the selected product code before purchase.

Immediate Answers

Frequently Asked Questions

Find technical, reprocessing, ordering, and size compatibility answers for the Bharat Surgical Aspiration Needle range.

It is a long-shaft needle instrument with an internal fluid pathway and connector intended for selected laparoscopic aspiration requirements.

The current detailed listing states a 16 G needle specification.

The main laparoscopic listing states 5 mm. A separate listing states 10 mm, so the correct diameter must be confirmed by product code.

A working length of 120 mm is published for the detailed model.

The instrument is listed with stainless-steel construction and a polished finish.

Yes. Bharat Surgical’s detailed listing describes it as reusable.

It is described as autoclavable, but hospitals must obtain the complete validated reprocessing cycle from the current IFU.

The published information is inconsistent. Confirm whether the selected model is supplied sterile or non-sterile.

Yes. A tubing connector is listed, but its exact dimensions and interface must be confirmed.

Tubing inclusion is not clearly specified. Request written confirmation in the quotation.

Not necessarily. Verify the connector type and the tubing’s internal diameter before purchase.

Not automatically. Compare the maximum instrument diameter with the trocar’s internal diameter and valve construction.

A reducer may be suitable when all dimensions and valve interfaces are compatible. Verify the complete combination before approval.

No. They are intended for different functions. A marketplace field uses the term “Veress,” but Bharat Surgical should confirm the selected product’s correct classification.

No. An aspiration needle has a needle-style distal end and generally a narrower lumen, while a suction–irrigation instrument uses a cannula or probe with model-specific flow controls.

It is the published needle-gauge specification. It should not be confused with the instrument’s outer shaft diameter.

No. The published model separately lists a 16 G needle and a 5 mm shaft diameter.

The internal lumen diameter is not clearly published. Request a dimensioned drawing if lumen size is important.

Follow the model-specific IFU and hospital’s validated CSSD procedure using compatible flushing and channel-cleaning equipment.

Inspect the openings and perform only the patency or flow test approved by the product IFU and hospital protocol.

It should be removed from service and assessed by qualified personnel. Do not attempt to straighten it in the operating department.

Inspect the tip, shaft, lumen, handle, connector, joints, surface condition and product markings.

Only if the current product-specific IFU permits it.

Use a tip-protection method that is compatible with the IFU and sterilization process and does not interfere with sterilant contact.

A technical sample may be requested, subject to availability and Bharat Surgical’s commercial policy.

Yes. Medical colleges can enquire about individual instruments or complete laparoscopic training sets.

Hospitals, dealers and distributors can request quantity-based quotations.

Provide the required gauge, diameter, length, tip type, connector, trocar size, tubing details, quantity and delivery location.

Request the technical sheet, product code, IFU, material confirmation, sterile-status declaration, connector details and current quotation.

OEM or private-label availability must be confirmed based on the required specification, quantity and destination market.

Request Laparoscopic Aspiration Needle Price

Aspiration Needle pricing varies according to technical specifications, quantity, packaging, and delivery destination. Send your configuration details to receive a current B2B quotation.
Factors Affecting Price: Needle gauge, Shaft diameter, Working length, Tip design, Internal lumen, Tubing connector, Stainless-steel grade, Reusable construction, Sterile or non-sterile supply, Tubing or adapter inclusion, Required documentation, Order quantity, Packaging, Domestic or export delivery, Taxes and freight