Bharat Surgical manufactures and supplies reusable Veress needles for hospitals, surgeons, surgical centres, dealers and medical-equipment distributors. The published range includes Veress needles in 100 mm, 120 mm, 140 mm and 160 mm lengths. Selected models feature a spring-loaded blunt inner tip mechanism and are available in different diameters or gauge configurations. Buyers should confirm the required length, diameter, material, connector and supplied components before ordering.
A Veress needle is a laparoscopic access instrument used by trained surgical professionals during the establishment of pneumoperitoneum before selected minimally invasive procedures.
A typical Veress needle incorporates an outer needle and a spring-loaded blunt inner stylet. However, the exact tip mechanism, connector, diameter and construction can vary between models.
A compact Veress needle configuration for buyers specifically requiring a 100 mm instrument. Confirm the actual available diameter, connector and material combination.
A reusable intermediate-length option listed within Bharat Surgical’s published Veress needle range.
A longer reusable configuration available for requirements where the surgical department specifies a 140 mm working length.
The published 160 mm model includes: The final gauge and diameter combination should be verified because gauge terminology and metric diameter are not always interchangeable across product listings.
| Specification | Published options |
|---|---|
| Product type | Laparoscopic Veress needle |
| Available lengths | 100, 120, 140 and 160 mm |
| Published diameter | Approximately 2 mm or 2.1 mm on the 160 mm model |
| Published gauges | 18G, 16G and 15G on selected listings |
| Tip mechanism | Spring-loaded blunt tip on the 160 mm model |
| Usage type | Reusable |
| Published materials | Stainless steel and brass references, depending on listing |
| Finish | Polished or mirror finish on selected models |
| Application | Laparoscopic and hospital use |
| Brand | Bharat Surgical |
| Country of supply | India |
Bharat Surgical publishes Veress needles in 100/120/140/160 mm sizes, while its 160 mm listing specifically identifies a reusable stainless steel model with an approximately 2–2.1 mm diameter and spring-loaded blunt tip. Bharat Surgical Veress Needle range, Veress Needle 160 specifications.
Because current listings refer to both brass and stainless steel, the exact construction of each length should be confirmed in the product quotation.
Specify whether the requirement is for 100 mm, 120 mm, 140 mm or 160 mm. Do not order only by writing “standard Veress needle.”
State the required metric diameter, gauge or both. Ask Bharat Surgical to confirm how the published gauge corresponds with the supplied needle diameter.
Selected models are listed with a spring-loaded blunt inner tip. Obtain confirmation for the exact model being ordered.
Current Bharat Surgical listings refer to brass and stainless steel. Ask whether the description applies to the entire instrument or to particular components such as the hub, shaft or connector.
If the Veress needle must connect with an existing insufflation tube or system, provide photographs and connector measurements.
Bharat Surgical’s principal published models are reusable. Ensure the quotation clearly identifies the usage type.
| Length | Procurement consideration | |
|---|---|---|
| 100 mm | Compact configuration; confirm current availability | |
| 120 mm | Intermediate length | |
| 140 mm | Extended intermediate length | |
| 160 mm | Long configuration with detailed published specifications |
The surgical department must select the appropriate length. Procurement teams should not substitute one length for another without approval.
Before ordering, confirm:
Procurement Notice: Ask whether the quotation covers a complete Veress needle or any separate replacement component.
The connection between the Veress needle and insufflation tubing must match the intended equipment setup.
Buyers should provide:
A Veress needle should not be described as universally compatible with every CO₂ insufflator or tubing system.
| Instrument | General procurement distinction | |
|---|---|---|
| Veress needle | Needle used during selected closed-access and insufflation workflows | |
| Laparoscopic trocar | Access instrument and cannula system used to establish an instrument port | |
| Hasson trocar | Trocar configuration associated with an open-access approach | |
| Safety trocar | Trocar incorporating a protective shield mechanism |
The surgeon or hospital determines the required access technique and instrument combination.
Read What Is a Veress Needle Used For?
Hospitals can procure Veress needles for:
A hospital BOQ should specify the required length, diameter, quantity, connector and documentation.
Bharat Surgical accepts Veress needle enquiries from surgical-instrument dealers, distributors and medical-equipment suppliers.
Provide:
Buyers may also require:
Reusable Veress needles contain narrow internal areas and a moving tip mechanism that require careful inspection.
The facility’s inspection process should follow the supplied instructions and may include:
The healthcare facility should obtain model-specific cleaning, flushing, inspection, sterilization, drying and storage instructions.
Sterilization Notice: Do not publish or apply a universal sterilization temperature or cycle without verified instructions for the supplied model.
Send the following details:
Exact material, diameter, gauge, connector, processing instructions, documentation and delivery terms should be confirmed through the applicable quotation.
Find technical, reprocessing, ordering, and size compatibility answers for the Bharat Surgical Veress Needle range.
A Veress needle is a laparoscopic access instrument used by trained surgical professionals during the establishment of pneumoperitoneum for selected minimally invasive procedures.
Yes. Bharat Surgical publishes reusable Veress needles in several length configurations.
The published range includes 100 mm, 120 mm, 140 mm and 160 mm options.
The 160 mm model is listed with an approximate diameter of 2 mm or 2.1 mm. Confirm the exact diameter for every selected length.
Selected listings mention 18G, 16G and 15G. Ask Bharat Surgical to confirm the available gauge and corresponding metric diameter.
The published 160 mm model includes a spring-loaded blunt tip. Confirm the mechanism for other lengths.
Current listings refer to stainless steel and brass. Confirm the exact material of the shaft, hub and other components for the selected model.
Yes. The principal published models are reusable.
The main difference is instrument length. Diameter, material and tip mechanism may also vary and must be confirmed separately.
The responsible surgeon or department should specify the required length. Procurement teams should not select a length without clinical confirmation.
No. They are different access instruments. A Veress needle is associated with selected insufflation workflows, while a trocar and cannula provide an instrument-access port.
No. Their intended purposes and construction differ. Order using the exact product name and required specification.
It may connect through compatible tubing and fittings. The connector and equipment compatibility must be verified.
No. Tubing connectors and system requirements can vary between equipment manufacturers and models.
Tubing inclusion depends on the quotation. Ask whether the price covers only the needle or includes compatible tubing and accessories.
Inspect the tip, spring mechanism, shaft, internal channel, connector and surface according to the supplied instructions.
Follow the model-specific reprocessing instructions, paying particular attention to the internal channel and moving stylet.
Yes. Hospitals can submit a size-wise requirement or include Veress needles in a consolidated laparoscopic-instrument BOQ.
Yes. Submit the required lengths, quantities, destination and packing requirements for commercial review.
Export buyers can submit the required specifications, destination country, quantity, packing and documentation requirements.
Send the required length, diameter or gauge, quantity, connector and delivery destination to receive a current quotation.
Veress needle prices can vary according to: Send the required specifications to receive a current written quotation.
Factors Affecting Price: Length, Diameter or gauge, Material and component construction, Tip mechanism, Connector design, Quantity, Packing, Documentation, Delivery destination