Bharat Surgical manufactures and supplies reusable TURP surgery instruments for hospitals, urology centres, medical colleges, surgical-equipment dealers and international distributors. The range includes monopolar resectoscope sets, 26 Fr inner and outer sheaths, active and passive working elements, compatible telescopes, electrodes and related accessories. A TURP instrument set must be configured as one compatible system — the sheath, telescope, working element, electrode, cable and electrosurgical generator must be matched by exact technology, dimensions and connection.
For professional healthcare use only. TURP instruments must be selected, configured and used by qualified medical professionals according to the applicable instructions for use. Bharat Surgical's published range includes:
Availability, dimensions and system compatibility should be reconfirmed in the final quotation.
TURP surgery instruments are components of a rigid transurethral resectoscope system. TURP refers to transurethral resection of the prostate.
A configured resectoscope system typically combines:
| Component | Function within the system | Details to confirm |
|---|---|---|
| Rigid telescope | Provides endoscopic visualisation | Diameter, length, viewing angle and light post |
| Inner sheath | Forms part of the continuous-flow assembly | Size, lock and outer-sheath compatibility |
| Outer sheath | Houses the inner sheath and flow connections | French size, length and stopcocks |
| Obturator | Fits the selected sheath during system setup | Size, profile, length and lock |
| Working element | Controls movement of the compatible electrode | Active/passive action, stem design and telescope size |
| Electrode | Provides the system-specific electrosurgical function | Monopolar/bipolar type, shape, size and connector |
| Cable | Connects the working element or electrode to the generator | Instrument-side and generator-side connections |
| Generator | Supplies approved electrosurgical output | Manufacturer, model, mode and accessory approval |
| Camera and light system | Displays and illuminates the endoscopic field | Coupler, telescope and light-cable compatibility |
| Irrigation connection | Connects the approved fluid-management arrangement | Stopcock, tubing and sheath configuration |
The generator and fluid-management arrangement are separate systems. A generator should not be described as controlling irrigation unless the exact integrated equipment documentation establishes that function.
Bharat Surgical currently publishes a 26 Fr TURP inner and outer sheath. The published specification is:
| Published specification | Details |
|---|---|
| Size | 26 Fr |
| Type | TURP inner and outer sheath |
| Material | Stainless steel |
| Material grade | SS 304 |
| Brand | Bharat Surgical |
| Minimum order quantity | 5 pieces |
| Published application | TURP surgery |
| Selection point | Monopolar system | Bipolar system |
|---|---|---|
| Electrical circuit | Uses an approved monopolar circuit | Uses the approved bipolar electrode system |
| Patient return electrode | Generally required as part of the monopolar setup | Determined by the specific bipolar system |
| Working element | Monopolar-compatible model | Bipolar-compatible model |
| Electrode | Monopolar electrode | Bipolar electrode |
| Cable | Monopolar system cable | Bipolar system cable |
| Generator | Compatible monopolar output | Compatible bipolar output |
| Fluid requirement | Must follow complete system IFU | Must follow complete system IFU |
| Interchangeability | Not interchangeable — verify each component independently | |
Only qualified healthcare professionals should select the technology, fluid medium and generator settings. A product described as "bipolar" is not automatically compatible with every bipolar generator or resectoscope platform.
The working element connects the telescope, sheath and compatible electrode and controls the electrode's mechanical movement. Bharat Surgical's range includes:
Active and Passive Working Elements
| Feature | Active | Passive |
|---|---|---|
| Resting position | System-specific active-action arrangement | System-specific passive-action arrangement |
| Electrode movement | Determined by handle and spring design | Determined by handle and spring design |
| Selection basis | Surgeon preference and system compatibility | Surgeon preference and system compatibility |
| Compatibility | Requires matching electrode, telescope and sheath in both cases | |
"Active" and "passive" describe mechanical action — they do not indicate whether the electrosurgical technology is monopolar or bipolar.
Single-Stem and Double-Stem Working Elements
| Feature | Single-stem | Double-stem |
|---|---|---|
| Construction | One defined structural stem | Two defined structural stems |
| Electrode compatibility | Model-specific | Model-specific |
| Telescope compatibility | Must be verified — not assumed | |
| Interchangeability | Not assumed | |
Depending on the approved resectoscope system, electrode configurations may include:
| Component | Must match |
|---|---|
| Telescope | Working element, sheath, viewing angle and imaging system |
| Inner sheath | Outer sheath, obturator and working element |
| Outer sheath | Inner sheath, flow arrangement and obturator |
| Working element | Telescope, sheath, electrode and technology |
| Electrode | Working element, telescope category, cable and generator |
| Cable | Instrument connector, generator socket and technology |
| Generator | Monopolar/bipolar system and approved accessories |
| Obturator | Exact sheath size, length, tip and lock |
| Stopcocks | Sheath threads and approved tubing |
| Camera/light equipment | Telescope eyepiece and light post |
Terms such as "Storz type" or "Stryker type" describe an intended compatibility reference and should be supported by exact catalogue numbers. Such wording does not mean the component is manufactured by the referenced OEM, that the trademark owner has approved the product, or that compatibility verification can be omitted. All third-party trademarks remain the property of their respective owners.
Before requesting a quotation, determine:
Authorised personnel should verify before every use:
Reusable TURP instruments contain narrow channels, locks, springs, hinges, insulation and electrical connectors that require validated cleaning and reprocessing. The FDA describes reusable-device reprocessing as a multistep process involving cleaning followed by appropriate disinfection or sterilisation.
Always follow each component's current IFU. Steam sterilisation should be used only when the IFU validates it for the exact component. The sheath, telescope, working element, electrode and cable may have different processing instructions.
Monopolar TURP Set BOQ
| Component | Suggested qty |
|---|---|
| Compatible rigid telescope | 1 |
| Inner and outer sheath | 1 set |
| Matching obturator | 1 |
| Monopolar working element | 1 |
| Compatible monopolar electrodes | As required |
| Compatible monopolar cable | 1 |
| Approved patient return accessories | As per generator IFU |
| Irrigation connectors | 1 set |
| Light cable | 1 |
| Camera coupler | 1 |
| Cleaning accessories | 1 set |
| Sterilisation tray | 1 |
Bipolar TURP Set BOQ
| Component | Suggested qty |
|---|---|
| Compatible rigid telescope | 1 |
| Inner and outer sheath | 1 set |
| Matching obturator | 1 |
| Bipolar working element | 1 |
| Compatible bipolar electrodes | As required |
| Compatible bipolar cable | 1 |
| Irrigation connectors | 1 set |
| Light cable | 1 |
| Camera coupler | 1 |
| Cleaning accessories | 1 set |
| Sterilisation tray | 1 |
These are procurement templates, not procedural setup guides. Final configurations must be approved by qualified clinical, biomedical and sterile-services personnel.
All dimensions, material grades, compatibility, supplied components, reusable status and regulatory documentation must be verified in the final quotation.
Technical, compatibility, ordering and reprocessing answers for the Bharat Surgical TURP Surgery Instruments range.
They are components of a rigid transurethral resectoscope system, including a telescope, sheath, working element, electrode and related accessories.
TURP means transurethral resection of the prostate.
Bharat Surgical publishes TURP sheaths, working elements, electrodes and a monopolar resectoscope-set category.
A configured set may be quoted after the technology and compatibility requirements are confirmed.
Bharat Surgical publishes a 26 Fr inner and outer sheath.
The published specification identifies 304-grade stainless steel.
The mathematical French-scale conversion is approximately 8.67 mm.
The published page states a minimum order quantity of five pieces. Current commercial terms should be reconfirmed.
It is the mechanism that connects with the telescope, sheath and compatible electrode and controls electrode movement.
It is a model with an active-action mechanical arrangement. Exact movement depends on the system design.
It is a model with a passive-action mechanical arrangement. Exact movement depends on the system design.
No. Active or passive describes mechanical action, not electrosurgical technology.
It is a working element constructed with one defined structural stem.
It is a working element constructed with two defined structural stems.
No universal interchangeability should be assumed.
They use different electrical systems, electrodes, cables, working elements and generator connections.
It should not be used unless that exact cross-compatibility is documented by the applicable system manufacturer.
A monopolar system generally uses an approved patient return arrangement. Follow the generator and accessory IFUs.
Fluid selection is a clinical and system decision governed by the complete device, generator and institutional instructions.
Published and model-dependent options may include loops, knives and ball or roller configurations. Confirm exact availability.
Bharat Surgical publishes a monopolar 2.9 mm TURP electrode category.
Bharat Surgical publishes monopolar and bipolar 4 mm TURP electrode categories.
No. It generally refers to the telescope category, not the complete assembled sheath diameter.
No. Length, viewing angle, lock and working-element interface must also match.
Only if specifically listed in the quotation. A generator is normally specified separately.
No. Both connectors, technology and electrical rating must be compatible.
Selected components may be reusable. Confirm each product's classification and IFU.
Not necessarily. Reusable design and supplied sterile condition are separate specifications.
Only when each component's IFU validates steam sterilisation.
Follow the IFU for disassembly, brushing, flushing, rinsing, drying and inspection.
Check mechanical movement, locks, springs, electrode seating, insulation and visible cleanliness.
Yes, subject to confirming compatibility with the telescope, sheath, electrode and generator system.
Yes, but the exact working element, telescope category, technology and generator must be identified.
Matching may be reviewed using catalogue numbers, dimensions, photographs or a physical sample.
It describes an intended compatibility reference and does not imply OEM manufacture, endorsement or universal fit.
Price depends on technology, components, dimensions, electrode quantity, compatibility, documentation and destination.
Provide the sheath, telescope, working element, electrode, cable and generator specifications.
Dealer, institutional and export enquiries may be submitted subject to availability and destination requirements.
Medical and Procurement Disclaimer: This page provides general product and procurement information for qualified healthcare organisations and medical-device buyers. It is not a clinical, electrosurgical or procedural instruction and does not replace professional training, clinical judgement, institutional protocols or product-specific instructions for use. Compatibility, fluid selection, generator settings, reprocessing, sterile supply and regulatory status must be verified before purchase and use.
TURP instrument pricing varies according to monopolar or bipolar technology, components, sheath size, working element, electrode type, quantity and delivery destination. Contact Bharat Surgical with the required system details, sheath size, telescope model, working-element type, electrode reference, generator model, quantity and delivery destination. For replacement components, include catalogue numbers and clear photographs of all interfaces.
Factors Affecting Price: Monopolar or bipolar technology, complete set or individual component, telescope category, sheath size, working-element design, electrode type and quantity, cable and generator compatibility, accessories, order quantity, sterilisation tray, documentation, delivery destination