MANUFACTURER & SUPPLIER | B2B UROLOGY INSTRUMENTS

TURP Inner Outer Sheath
Manufacturer and Supplier in India

Bharat Surgical manufactures and supplies reusable inner–outer sheath assemblies for compatible TURP resectoscope systems. The product is intended for hospitals, urology departments, surgical centres, medical-equipment dealers and international distributors seeking replacement sheaths or components for a complete resectoscope set. The sheath is not a universal accessory. Its size, working length, locking mechanism, irrigation arrangement, obturator and connection with the telescope and working element must match the selected resectoscope platform.

ISO 13485:2016 Certified
40+ Years Experience
Mumbai Warehousing
Inner Outer Sheath surgical instrument on a clean clinical blue background
Overview

What Is an Inner Outer Sheath?

An inner–outer sheath is a paired sheath assembly used with a compatible resectoscope system. The outer sheath forms the external passage, while the inner sheath fits inside the outer component and supports the system’s telescope, working element and irrigation arrangement.

Depending on the exact design, the system may include:

Outer sheath
Inner sheath
Matching obturator
Inflow and outflow ports
Stopcocks
Locking mechanism
Telescope
Working element
Compatible electrode
Light cable
Camera system

The inner and outer sheaths must be matched to each other. Similar appearance or nominal French size does not prove that components from different models will assemble or function correctly.

Matching Notice

The two components should be purchased as a matched pair unless Bharat Surgical confirms that an individual replacement is compatible with the buyer’s existing component.

Clinical selection and use must follow the applicable instructions for use and institutional protocols.

Specifications & Components

Bharat Surgical TURP Inner Outer Sheath & System Components

Bharat Surgical publishes a TURP Inner Outer Sheath 26 Fr with the following specifications:

Published specificationBharat Surgical listing
ProductTURP Inner Outer Sheath
Size26 Fr
UsageTURP surgery
TypeTURP sheath
MaterialStainless steel
Material gradeSS 304
BrandBharat Surgical
Published minimum order quantity5 pieces

These details come from Bharat Surgical’s current TURP Inner Outer Sheath 26 Fr listing. The published page identifies the assembly as 26 Fr but does not separately state the nominal size of the inner component. That dimension should therefore be confirmed in the written quotation rather than inferred.

Components of an Inner–Outer Sheath System

Outer Sheath: The outer sheath is the larger external component. Depending on its design, it may include fluid ports, stopcocks, a distal profile and a locking interface for the inner sheath.

Inner Sheath: The inner sheath fits into the matching outer sheath. It helps create the required system pathway and irrigation arrangement for compatible components.

Obturator: An obturator may be used with the matching sheath during system placement. It must correspond to the exact sheath profile, size, length and locking arrangement.

Inflow and Outflow Ports: A continuous-flow sheath system may include separate irrigation inflow and outflow paths. Buyers should confirm the number of ports, connector type, stopcock design and compatible tubing.

Locking Mechanism: The locking mechanism connects the sheath components to each other and to the remaining resectoscope assembly. Lock styles are model-specific and should not be forced together.

Comparison & Dimensions

Inner vs Outer Sheath & 26 Fr Dimensions

Inner Sheath vs Outer Sheath

FeatureInner sheathOuter sheath
PositionFits inside the outer componentForms the larger external component
SizeSmaller than the matching outer sheathLarger nominal profile
Primary relationshipConnects with telescope and working assembly according to system designReceives the matching inner sheath
Fluid pathwayModel-dependentCommonly incorporates one or more ports
Locking interfaceMust match outer sheath and resectoscope componentsMust match inner sheath and obturator
ReplacementRequires exact system identificationRequires exact system identification

The two components should be purchased as a matched pair unless Bharat Surgical confirms that an individual replacement is compatible with the buyer’s existing component.

26 Fr TURP Sheath

Bharat Surgical publishes its inner–outer sheath in a 26 Fr configuration. French size is a nominal diameter measurement:

Diameter in millimetres ≈ French size ÷ 3

Therefore, 26 Fr corresponds nominally to approximately 8.67 mm. This conversion is for basic procurement understanding only. It does not establish:

Exact internal diameter
Inner-sheath size
Wall thickness
Working length
Obturator compatibility
Telescope fit
Locking-system compatibility
Working-element compatibility

Do not assume the unpublished inner-sheath size based on common market combinations. Obtain the exact measurement from Bharat Surgical.

Material & Compatibility

Stainless-Steel Construction & Resectoscope Compatibility

Stainless-Steel Construction

Bharat Surgical identifies stainless steel, grade SS 304, for its published 26 Fr TURP sheath.

Before purchase, institutional buyers may request confirmation of:

Material grade
Surface finish
Corrosion-resistance requirements
Reusable status
Sterile or non-sterile delivery
Reprocessing method
Repair or replacement availability
Material declaration
Product traceability
Packaging format

Material grade alone does not confirm compatibility, service life or suitability for a particular sterilisation cycle.

TURP Resectoscope Compatibility

A complete TURP resectoscope system may combine:

Inner and outer sheath
Obturator
Telescope
Working element
Electrode
Electrosurgical generator
Generator cable
Light cable
Camera head and coupler
Irrigation tubing and fluid-management equipment

Each component has a separate compatibility requirement. The sheath must match both the mechanical resectoscope assembly and the intended irrigation configuration.

Compatibility Matrix

ComponentInformation to verify before ordering
Outer sheathFrench size, length, distal profile and locking interface
Inner sheathExact outer-sheath model, nominal size and connection
ObturatorSheath size, profile, tip and locking system
TelescopeDiameter, angle, working length and interface
Working elementActive or passive, stem design and sheath compatibility
ElectrodeMonopolar or bipolar system, size, shape and working-element fit
GeneratorBrand, model, supported energy mode and cable
Light cableTelescope-side and light-source-side connectors
Camera systemCamera head, coupler and telescope eyepiece
Irrigation tubingPort design, connector and system requirements
StopcockPort size, thread and sheath model
Sterilisation traySheath length, layout and reprocessing suitability
System Engineering

Working Elements, Electrosurgery & Flow Design

Active and Passive Working Elements

Bharat Surgical publishes active and passive working elements in different stem arrangements. The selected working element must be mechanically compatible with the sheath, telescope and electrode. Do not assume that:

Every active element fits the 26 Fr sheath
Every passive element fits the 26 Fr sheath
Single-stem and double-stem elements are interchangeable
A monopolar element accepts a bipolar electrode
A laser working element fits the same sheath
“Stryker type” or other descriptive wording proves compatibility

The complete system should be verified by model and technical drawing wherever possible.

Monopolar and Bipolar TURP Compatibility

The terms monopolar and bipolar describe different electrosurgical system configurations. The sheath alone does not determine whether a complete setup is monopolar or bipolar. Compatibility depends on the combination of:

Working element
Electrode
Electrosurgical generator
Connecting cable
Telescope
Sheath
Irrigation requirements
Manufacturer-approved configuration

Never mix monopolar and bipolar components without written confirmation that the complete system is designed and approved for that combination.

Continuous-Flow Configuration

An inner–outer sheath assembly may support continuous irrigation through separate fluid paths. Bharat Surgical’s product description refers to uninterrupted irrigation as part of the published TURP sheath configuration.

For procurement, buyers should confirm:

Whether the quoted model is continuous flow
Number of stopcocks
Inflow and outflow identification
Tubing-connector size
Seal condition
Permitted pressure or fluid-management system
Complete flow-path cleaning instructions

The published reference to irrigation does not replace the system manufacturer’s operating instructions.

Rotatable and Non-Rotatable Sheaths

Resectoscope sheaths may be offered in rotatable or non-rotatable configurations in the wider market. Bharat Surgical’s published 26 Fr listing does not clearly identify its quoted model as rotatable or non-rotatable.

This detail should be included in the quotation request and confirmed before purchase. Do not infer rotation capability from general promotional wording about working-element movement.

Reusable and Sterile Status

A stainless-steel inner–outer sheath is generally supplied as a reusable surgical instrument. However, the exact reusable status and delivered sterile condition must appear on the quotation, product label or instructions for use. Buyers should distinguish between:

Reusable and supplied sterile
Reusable and supplied non-sterile
Sterile single-use accessory
Non-sterile replacement component

If the sheath is supplied non-sterile, it must undergo the validated cleaning and sterilisation process before first use.

Quality & Reprocessing

Inspection, Reprocessing and Maintenance

Pre-Use Inspection

Before every use, trained personnel should check:

Correct inner and outer sheath pairing
Correct product size
Cleanliness and processed status
Bends, dents, cracks or corrosion
Distal-tip deformation
Rough or damaged surfaces
Lumen obstruction
Secure and functional stopcocks
Port and connector integrity
Leakage from joints
Smooth inner-sheath insertion
Reliable locking and release
Correct obturator fit
Telescope alignment
Working-element movement
Electrode clearance
Complete assembly stability

Do not use the assembly if any component is damaged, incorrectly matched, difficult to lock or uncertain in cleanliness.

Cleaning, Disinfection and Sterilisation

Reusable inner and outer sheaths contain channels, stopcocks, joints and narrow spaces that must be cleaned thoroughly. Reprocessing must follow Bharat Surgical’s validated instructions for the exact product.

The FDA describes reprocessing as a detailed multistep process involving cleaning followed by the required disinfection or sterilisation. It also stresses that complex reusable devices need clear, validated reprocessing instructions. See the FDA reusable-device reprocessing information and medical-device reprocessing guidance.

General controls may include:

Begin point-of-use treatment as instructed
Prevent contamination from drying
Separate detachable components
Open or remove stopcocks where directed
Flush every irrigation pathway
Brush accessible lumens with the specified brush
Use approved detergent and water quality
Rinse internal and external surfaces
Dry channels completely
Inspect under suitable lighting
Check for retained debris and corrosion
Reassemble and function-test
Package in a compatible sterilisation tray
Apply only the validated sterilisation cycle
Protect processed products during storage

Do not publish one universal autoclave temperature, exposure time or chemical concentration unless it appears in the product-specific instructions.

Maintenance and Storage

After reprocessing and inspection:

Store the sheath in a suitable tray
Avoid stacking heavy instruments over it
Protect distal ends and stopcocks
Keep matched inner and outer components together
Maintain product identification
Avoid contact with incompatible metals or chemicals
Follow the facility’s sterile-storage policy
Record repair or replacement history where required

Do not straighten, grind, polish or modify a damaged sheath inside the hospital unless the work is performed through an authorised repair process.

Procurement

Inner Outer Sheath BOQ Template

BOQ itemSpecification to provideQuantity
Inner–outer sheath set26 Fr, interface and working length___
Outer sheathSize, port configuration and lock___
Inner sheathExact matching outer-sheath model___
ObturatorSize, profile and sheath compatibility___
Stopcock setPort type and connection___
TelescopeDiameter, angle and working length___
Working elementActive/passive and stem configuration___
ElectrodeMonopolar/bipolar, size and shape___
Generator cableGenerator and working-element compatibility___
Light cableScope-side and source-side connectors___
Camera couplerTelescope and camera interface___
Irrigation tubingPort connector and system requirement___
Seal or washer setExact sheath model___
Sterilisation traySize and required contents___
Spare sheath setExact model and quantity___
B2B Supply

Supply Channels, Export and Pricing Factors

For Hospitals and Urology Centres

Hospitals may request:

New 26 Fr inner–outer sheath assemblies
Replacement inner or outer components
Matching obturators
TURP resectoscope set configurations
Backup sheaths for operating theatres
Working-element compatibility checks
Tender-specific BOQs
Reusable urology instrument sets

Where an original reference number is unavailable, provide clear photographs of the sheath, locks, ports, distal end and existing components.

For Dealers and Distributors

Dealers and distributors may request:

Product-wise quotations
Published minimum-order details
Bulk-order pricing
Technical specification sheets
Product photographs
Replacement-system matching
Dealer packing
Tender documents
Export packaging
Dealership discussions

The published minimum order quantity for the Bharat Surgical 26 Fr listing is five pieces. Buyers should reconfirm the applicable MOQ in the current quotation because commercial terms can change.

Export Enquiries

International buyers should specify:

Destination country
Required quantity
Sheath size
Inner and outer component requirement
Working length
Locking interface
Obturator requirement
Telescope and working-element models
Sterile or non-sterile delivery
Packaging and language requirements
Requested certificates
Required delivery schedule

The importer must confirm local medical-device registration, labelling and import requirements.

Inner Outer Sheath Price

The price depends on:

Complete set or individual component
French size
Working length
Locking arrangement
Rotatable or non-rotatable design
Number of stopcocks
Obturator inclusion
Material and finish
Supplied seals or accessories
Order quantity
Packaging and documentation
Domestic or export delivery

Requesting only “TURP sheath” is insufficient for accurate pricing. Submit the complete system specification.

Information Required for a Quotation

Please provide:

Buyer or institution name
Delivery city and country
Required quantity
Existing sheath brand and model
Outer-sheath French size
Inner-sheath size, if known
Working length
Rotatable or non-rotatable requirement
Telescope details
Working-element details
Electrode system
Obturator requirement
Port and stopcock configuration
Photographs of all connections
Tender or export documentation
Expected delivery date
Immediate Answers

Frequently Asked Questions

Technical, compatibility, ordering and reprocessing answers for the Bharat Surgical TURP Inner Outer Sheath range.

It is a matched sheath assembly used with a compatible TURP resectoscope system.

Yes. Bharat Surgical publishes a 26 Fr stainless-steel TURP inner–outer sheath.

The current published product is identified as 26 Fr.

Bharat Surgical’s published page does not separately state it. The exact inner-sheath size must be confirmed in the quotation.

The published Bharat Surgical product is made from stainless steel.

Bharat Surgical lists SS 304 for its published 26 Fr sheath.

It is designed for a compatible TURP resectoscope system used by trained urology professionals.

It is a nominal French-size measurement corresponding to approximately 8.67 mm.

Not necessarily. The published listing identifies the overall product as 26 Fr but does not separately specify the inner component.

No. Size, length, lock, profile and system interface must all match.

An individual replacement may be possible, but compatibility with the existing outer sheath must first be confirmed.

It may be quoted separately subject to exact model identification and compatibility confirmation.

The buyer should verify this in the written quotation. Do not assume that it is included.

No. Tip, length, profile and locking mechanism vary.

The published description refers to an irrigation-capable sheath, but the number and design of supplied stopcocks should be confirmed.

The published product description refers to uninterrupted irrigation. Confirm the exact flow arrangement and supplied parts in the quotation.

The published specification does not clearly confirm this. Buyers should request written verification.

No. Telescope diameter, length and interface must match the sheath assembly.

No. Active/passive design, stem arrangement, length and locking connection must be checked.

Do not assume this. Compatibility depends on the complete resectoscope, working element, electrode and generator system.

Only if Bharat Surgical confirms the exact mechanical and system compatibility.

No. Components may connect physically but still have incorrect alignment, clearance, insulation or operating characteristics.

A stainless-steel TURP sheath is generally offered as reusable, but the final product label and IFU must confirm its status.

The sterile or non-sterile delivery condition must be confirmed for the quoted product.

Yes. It must be cleaned and sterilised according to the product-specific validated instructions.

Use only the sterilisation method and parameters stated in the supplied IFU.

Flush and brush all accessible pathways using the method and brush sizes specified by the manufacturer.

Follow the product IFU. Matched components commonly require disassembly so their surfaces and channels can be accessed.

Check cleanliness, straightness, lumen patency, surface condition, stopcocks, locks, obturator fit and complete-system assembly.

Remove it from service and obtain an authorised assessment. Uncontrolled straightening may affect alignment and integrity.

Stop using it and inspect the ports, stopcocks, seals and joints according to the approved maintenance process.

Photographs help, but the original model, sizes, length and connection details are also required.

Send the full sheath, distal tip, locks, ports, markings and mating components from several clear angles.

The current Bharat Surgical product page lists a minimum order quantity of five pieces.

Hospitals can request a quotation, but the accepted quantity depends on Bharat Surgical’s current commercial terms.

Yes. Dealer pricing depends on quantity, configuration, packing and destination.

Export enquiries may be accepted subject to availability, documentation and destination-country requirements.

Provide the exact sheath size, system details, required components, quantity and delivery location.

Medical and Procurement Disclaimer: TURP inner–outer sheaths are intended for use by appropriately trained healthcare professionals as part of a compatible resectoscope system. This page provides general product and procurement information and is not a procedural guide. Dimensions, supplied components, sterile status, reusable status, compatibility, certifications, availability and minimum quantities may change. Confirm every specification through Bharat Surgical’s current written quotation, product label and instructions for use before purchase, reprocessing or clinical use.

Request Inner Outer Sheath Price

The price depends on complete set or individual component, French size, working length, locking arrangement, rotatable or non-rotatable design, number of stopcocks, obturator inclusion, material and finish, supplied seals or accessories, order quantity, packaging and documentation, and domestic or export delivery. Requesting only “TURP sheath” is insufficient for accurate pricing. Submit the complete system specification.