The Bi-TURP Set from Bharat Surgical is a configurable bipolar resectoscope system designed for transurethral electrosurgical procedures in urology. A complete set typically combines a telescope, inner and outer sheaths, obturator, bipolar working element, compatible electrodes and electrical connections for controlled resection and coagulation under endoscopic visualization.
Bharat Surgical manufactures TURP sheaths, bipolar electrodes and several active and passive working-element configurations. Because the company’s public catalogue does not provide one fixed Bi-TURP packing list, hospitals and distributors should obtain a component-wise quotation based on their telescope, generator and procedural requirements.
A Bi-TURP Set—also called a Bipolar TURP Resectoscope Set—is an endoscopic instrument system used for selected transurethral urological procedures.
In a bipolar system, the electrosurgical circuit is completed locally between:
This localized bipolar arrangement commonly permits the use of normal saline as the irrigation medium.
| Specification | Available or Configurable Detail |
|---|---|
| Product name | Bi-TURP Set |
| Alternate name | Bipolar TURP Resectoscope Set |
| Product category | Endourology and resectoscopy instruments |
| Energy system | Bipolar |
| Telescope | Diameter, length and viewing angle to be confirmed |
| Sheath | 26 Fr Bharat Surgical model available |
| Sheath arrangement | Inner and outer continuous-flow configuration |
| Working element | Bipolar active or passive configuration |
| Stem arrangement | Single or double stem according to system |
| Electrode options | Cutting loop, Collins knife and ball electrode |
| Irrigation medium | Normal saline commonly used; follow system IFU |
| Electrical cable | Generator-specific bipolar cable |
| Generator | Compatible bipolar electrosurgical generator required |
| Main material | Stainless steel with optical, insulating and sealing components |
| Reuse | Reusable metal and optical components expected; confirm each item |
| Brand | Bharat Surgical |
| Country of origin | India |
Bharat Surgical currently lists the following relevant products:
These products indicate that Bharat Surgical can configure different TURP systems, but they should not all be assumed to be included in one Bi-TURP Set.
Depending on the supplied components, generator and approved instructions, a Bi-TURP Set may be considered for:
The final clinical application remains subject to the surgeon’s assessment and each component’s IFU.
| Selection factor | Bi-TURP Set | Monopolar TURP Set |
|---|---|---|
| Energy circuit | Completed locally within the resectoscope system | Passes through the patient to a return electrode |
| Irrigation medium | Commonly normal saline | Approved non-conductive medium |
| Remote return pad | Generally not part of the bipolar treatment circuit | Normally required |
| Working element | Bipolar-compatible | Monopolar-compatible |
| Electrode & cable | Bipolar loop/electrode and generator-specific cable | Monopolar loop/electrode and generator-specific cable |
| Fluid concern | Saline volume overload remains possible | Hypotonic-fluid absorption and TUR syndrome are concerns |
| Interchangeability | Must not be assumed | Must not be assumed |
Normal saline is electrically conductive and is commonly used in bipolar transurethral systems because the current path is completed locally within the bipolar resectoscope arrangement. Compared with hypotonic, non-conductive media, saline avoids dilutional hyponatremia associated with classic TUR syndrome. However, excessive absorption can still cause volume overload, pulmonary oedema, cardiovascular stress, and hyperchloremic metabolic acidosis.
Preoperative Inspection: Inspect telescope, sheaths, locks, stopcocks, obturator, working element, electrodes, insulation, cable and generator connection.
Irrigation pressure, inflow, outflow, procedure duration and patient condition still require clinical monitoring.
Disassemble components, pre-clean promptly, flush irrigation channels, clean lumens with compatible brushes, clean joints/locks, rinse thoroughly, dry completely, inspect, package, and sterilize using component-specific parameters.
Bharat Surgical supplies configurable Bi-TURP Sets, bipolar working elements, 26 Fr sheaths, and replacement components to hospitals, urology departments, dealers, and export buyers.
When requesting a quotation, please provide:
Technical, component, compatibility and safety answers for the Bharat Surgical Bi-TURP Set range.
A Bi-TURP Set is a bipolar resectoscope system used for selected transurethral electrosurgical procedures in urology.
Yes. “Bi-TURP” is commonly used as a short form for bipolar transurethral resection of the prostate.
A complete set may include a telescope, inner and outer sheaths, obturator, bipolar working element, electrodes and cable. The exact Bharat Surgical packing list must be confirmed.
Yes. Bharat Surgical lists a 26 Fr stainless-steel inner and outer TURP sheath.
It should not be assumed. Request written confirmation of the telescope diameter, angle, length and inclusion.
Bharat Surgical lists bipolar cutting loops, Collins knife electrodes and ball electrodes.
Bipolar TURP systems commonly use normal saline, subject to the electrode, generator and resectoscope instructions.
No. Excessive absorption can still cause volume overload and cardiopulmonary or acid–base complications.
A dedicated bipolar circuit generally completes current locally. Follow the generator instructions, particularly if other monopolar equipment is also used.
No. The generator must support the required bipolar TURP mode and connector system.
Cable inclusion is not confirmed. It should be separately listed in the quotation.
It is a working element whose manual and spring action move the electrode according to an active-system mechanism.
It uses a different manual and spring-return action. The electrode must match the passive mechanism.
Not automatically. Length, stem, movement and connector compatibility must be verified.
It is a configurable working element that may include an additional fitting for approved monopolar accessories. Exact compatibility must be confirmed.
No assumption should be made. Conventional monopolar systems require an approved non-conductive fluid, while bipolar TURP commonly uses saline.
Only if the complete system and supplied components are approved for that procedure and the surgeon determines it is appropriate.
The sheaths, working element and telescope are generally reusable system components. Each electrode and accessory must be individually confirmed.
Follow the component-specific IFUs. The telescope, seals, electrodes and stainless-steel parts may have different processing requirements.
Inspect the telescope, sheaths, locks, stopcocks, obturator, working element, electrodes, insulation, cable and generator connection.
Medical and Procurement Disclaimer: Component lists, telescope specifications, electrode quantities, compatibility, pricing, lead time and certifications must be confirmed through current Bharat Surgical documentation. Next Level 4 page: URS Handle.
Contact Bharat Surgical for complete bipolar TURP resectoscope sets, 26 Fr inner and outer sheaths, active or passive working elements, single-stem and double-stem systems, hybrid bipolar-monopolar working elements, bipolar cutting loops, Collins knife and ball electrodes, hospital procurement, dealer/distributor supply, bulk orders, export requirements, and tender enquiries.